Vitocrossal 200 CI2 Installation

Placement of Boiler

Positioning boiler
The boiler must be placed on a load bearing foundation.
This allows for the connection of a neutralization system.
Reducing Boiler Height

WiFi Operational Reliability and System Requirements

WiFi router system requirement
WiFi router with activated WiFi:
The WiFi router must be protected by a sufficiently
secure WPA2 password.
The WiFi router must always have the latest firmware
update.
Do not use unencrypted connections between the
boiler and the WiFi router.
Internet connection with high availability:
Flat rate (flat rate tariff without restriction on time or
data volume)
Dynamic IP addressing (DHCP, factory setting) in the
network (WiFi):
Have this checked on site, and if required set up, by
an IT expert prior to commissioning.
Set routing and security parameters in the IP network (LAN):
Enable port 80, port 123, port 443 and port 8883 for
direct outward connections.
Have this checked and, if necessary, set up on site
by an IT expert before commissioning.
Without seismic feet
Note: The levelling feet must be used once the boiler has
1. Using an open end wrench adjust the levelling feet in
2. It is recommended to place a flat piece of steel plate
3. Level the boiler, by adjusting the levelling feet.
(continued)
Wireless signal range of WiFi connection
The range of wireless signals may be reduced by walls,
ceilings and interior fixtures. These weaken the wireless
signal, causing poor reception due to the following
circumstances.
Install the boiler as close as possible to the WiFi router to
ensure a good WiFi connection. The signal strength can
be displayed on the boiler (see the operating instructions).
Note: The WiFi signal strength can be increased with
CI2
399
500
750 1000
Model
32
a
in.
812
mm
39b
b
in.
39b
39b
1000
1000
1000
mm
Weight
1027 lb.
incl.
water
358 kg
content
been placed in it's final position.
the base frame of the boiler ensuring that the wheels
are off the ground.
under each leveling bolt for better weight distribution
and adjustment.
On their way between transmitter and receiver, wireless
signals are damped, e.g. by air or when penetrating
walls.
Wireless signals are reflected by metallic objects,
e.g. reinforcements embedded in walls, metal foil of
thermal insulation and thermal glazing with metallized
thermal vapor deposit.
Wireless signals are isolated by service ducts and
lift shafts.
Wireless signals are disrupted by devices that also
operate with high frequency signals. Maintain a
distance of at least 6 ft. (2 m) from these devices:
– Computers
– Audio and video systems
– Devices with active WiFi connection
– Electronic transformers
– Pre-ballasts
commercially available WiFi repeaters.
Preinstallation
1500
2000
41
47
a
1040
1200
39b
39b
39b
1000
1000
1000
1382 lb.
2754 lb.
2798 lb.
627 kg
1249 kg
1269 kg
11