  • ENGLISH, page 12
▶ Long press the filter button
interface changes between the tree messages and then returns to the
original screen.
Fig. 24 Reseting filter messages
To check the filter status, press the filter button
lifetime of the filter will be displayed and then returns to the previous
screen.
6

Moving and storage

Moving
• Use two hands to hold the appliance when moving it.
Air 6000 – 6721848696 (2022/02)
to reset the filter lifetime counter. The
0010043306-001
. The remaining
• Hold the handle on top of the back cover of the appliance to keep the
appliance stable during transportation.
Storage
▶ Turn off the air purifier and unplug it from the power socket.
▶ Clean the air purifier, the particle sensor and the surface of the filter
( Chapter 5 "Cleaning and maintenance", Page 18).
▶ Let all parts airdry before storing.
▶ Wrap the filter in air-tight plastic covers.
▶ Store the air purifier and the filter in a cool, dry location.
▶ Wash your hands after handling the filter.
7

Troubleshooting

This chapter summarizes the most common issues that may occur with
the appliance. If the solution is not found in the table below, please
contact an authorized service technician.
Problem
The appliance does not work even
though it is plugged in.
The airflow that comes out of the
air outlet is significantly weaker
than before.
The air quality does not improve,
even though the appliance has
been operating for a long time.
The color of the air quality light
always stays the same.
Moving and storage
Possible solution
The filter lifetime alert has been on
continuously but the filter has not
been replaced. As a result, the
appliance is now locked. In this
case, replace the filter and long
press
to reset the filter lifetime
counter.
The surface of the filter is dirty.
Clean the surface of the filter
( Chapter 5 "Cleaning and
maintenance", Page 18).
• Check if the plastic cover is
removed from the filter.
• The filter has not been placed in
the appliance. Make sure that
the filter is properly installed.
• The particle sensor is wet. The
humidity level in the room is
high and causes condensation.
Make sure that the particle
sensor is clean and dry
( Chapter 5 "Cleaning and
maintenance", Page 18).
• Room size is large or the
outdoor air quality is poor. For
optimum purification
performance, close the doors
and windows when operating
the air purifier.
• There are indoor pollutants.
For example, smoking,
cooking, incense, perfume or
alcohol.
• Filter has reached the end of
life. Replace the filter with a
new one.
The particle sensor is dirty. Clean
the particle sensor ( Chapter 5
"Cleaning and maintenance",
Page 18). If the air quality is good,
the light should be blue at all times.
21