Toshiba TLP510U Service Manual page 21

3lcd data projector
Hide thumbs Also See for TLP510U:
Table of Contents

Advertisement

3. Click the
button on the C gain group, and
Level Adjust
check the luminance level of the white section is
automatically set to 100 ± 10%. If not, move the chart
position so that the white section is located at left side
of the screen and then click the
again.
4. While observing the vector scope, adjust C Gain
buttons until the R spot is located at center of
Fig. 4-1-9
button
Level Adjust
.
1-19
4-1-6. Camera Shipping Adjustment
• Test point
: ––
• Test equipment : ––
• Adjusting point : ––
• Adjusting value : ––
1. Click the
Exit...
button, and a dialogue box will
appear on the screen. This completes the camera
shipping adjustments.
Message
Adjustment is successful.
Fig. 4-1-10
Note:
If an error message will appear, check following items.
• Camera power is on.
• Camera and personal computer (COM1 port) are
connected.
OK