Uflex Velair i10 VSD SMART Installation And User Manual

Self-contained unit

Advertisement

Quick Links

Installation and user manual
(Translation of original
EN
instructions)
N420881A - Rev. 00 - 11/2022
Self-contained unit
i10 VSD SMART
i16 VSD SMART

Advertisement

Table of Contents
loading

Summary of Contents for Uflex Velair i10 VSD SMART

  • Page 1 Installation and user manual (Translation of original instructions) N420881A - Rev. 00 - 11/2022 Self-contained unit i10 VSD SMART i16 VSD SMART...
  • Page 2 We are sure you will be satisfied because it represents the best technology of boat air conditioning. By following the suggestions contained in this manual, the product you have purchased will operate without problems giving you optimum room temperatures with minimum energy costs. UFLEX S.r.l. Conformity This unit complies with the European directives: •...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS General information � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � p. 6 1.1 About the manual .
  • Page 4 3.11 Installation minimum distances ........p. 15 3.12 Positioning .
  • Page 5 5.2.1 Air intake filter cleaning ........p. 28 Troubleshooting � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � p. 29 6.1 Troubleshooting table .
  • Page 6: General Information

    GEnERAL InFORMATIOn GENERAL INFORMATION 1�1 About the manual This manual was written to provide all the explanations for The white numbers in black marks indicate a se- the correct management of the appliance. ries of actions to be carried out in sequence. T he black letter in white identifies an image when This instruction manual forms an integral part of the there are several images in the same figure.
  • Page 7: General Warnings

    GEnERAL InFORMATIOn It contains general information and important warnings Commissioning, maintenance and troubleshooting that should be known before installing and using the ap- They are addressed exclusively to the Technical Assistance pliance. Centre. It contains specific warnings useful information for the Product presentation most common commissioning and routine maintenance.
  • Page 8: Basic Rules Of Security

    GEnERAL InFORMATIOn 1�3 Basic rules of security Please keep in mind that the use of products powered by It is forbidden to open the access doors of the device's electricity and water call for operators to comply with cer- internal parts without first having set main switch of the tain essential safety rules: system to" off".
  • Page 9: Product Presentation

    PRODUCT PRESEnTATIOn PRODUCT PRESENTATION 2�1   I dentification The appliance can be identified by the rating plate: Technical rating plate Tampering with, removal of, or lack of identification This shows the technical and performance specifications of plates will not allow for the safe identification of the the appliance. product by its serial number and therefore invalidates the warranty.
  • Page 10: List Of Components

    PRODUCT PRESEnTATIOn 2�4 List of components 1� Sea-side heat exchanger 6� 4-way valve 2� 7� Air filter 3� 8� Inverter driven rotary compressor Room-side heat exchanger 4� 9� Electrical panel Condensate collection tray 5� Electronic expansion valve 2�5 Compatible accessories The choice and installation of accessories must be estab- lished by the system designer or other qualified profes- sional and must take into account both technical require- ments and any local laws in force.
  • Page 11: Installation

    InSTALLATIOn INSTALLATION 3�1 Preliminary warnings This section is dedicated to the Installer. The fea- Be sure to use the supplied or specified installation tures of the installer are described in the "Recipi- parts. Use of other parts may cause the unit to come to ents"...
  • Page 12: Movement Methods

    InSTALLATIOn 3�4 Handling with packaging 3�4�1 Preliminary warnings 3�4�2 Movement methods The appliance must be handled only by qualified per- sonnel, adequately equipped and with equipment suit- able for the weight and dimensions of the appliance. Before moving the unit, check the lifting capacity of the machinery used following the instructions on the pack- aging.
  • Page 13: Remove The Package

    InSTALLATIOn 3�7 Remove the package 1� Strapping 3�7�1 Accompanying material Remove the packing: – cut the strapping They are included with the appliance, inside the packaging: – remove the packing • 4 unit fixing brackets – remove the polystyrene elements Check the presence of the individual components. 3�8 Handling without packaging 3�8�1 Preliminary warnings To handle:...
  • Page 14: Installation Site

    InSTALLATIOn 3�9 Installation site The location of the appliance must be determined by the Make sure that: plant engineer or a competent person and must take into • the installation site of the unit must be chosen with account both purely technical requirements and any na- the utmost care to guarantee adequate protection tional/local legislation in force.
  • Page 15: Installation Minimum Distances

    InSTALLATIOn 3�11 Installation minimum distances 1� The clearance zones are necessary to avoid barriers to air- Air intake 2� Air delivery flow and to allow normal cleaning and maintenance. Make sure that there is sufficient space to allow for rou- tine and supplementary maintenance operations. 3�12 Positioning 3�12�1 Preliminary warnings Make sure that: • the supporting surface supports the weight of the appliance The unit must be fixed to the supporting surface.
  • Page 16: Preliminary Warnings

    InSTALLATIOn 3�13 Hydraulic connections 3�13�1 Preliminary warnings 3�13�3 Connection to the system The engineer is responsible for choosing the right wa- Preliminary warnings ter lines and their size, in accordance with good instal- lation practices and the applicable law. To allow maintenance or repair operations, each hy- draulic connection must be equipped with the respec- The hydraulic system is made by the installer and must tive manual shut-off valves.
  • Page 17 InSTALLATIOn Water line 3� Filter 4� Boat Ball valve 1� 5� Unit Inlet flow uphill 2� 6� Seawater pump Output flow...
  • Page 18: Filtration System

    InSTALLATIOn Connection • filtering system • ball valve To make the connections: – hydraulic lines positioning 3�13�4 Filtration system – connect to unit couplings with hose clamps – check for leaks It is necessary to install a filtration system at the The hydraulic connections must be completed by in- inlet of the appliance in an area accessible for stalling:...
  • Page 19: Position And Dimensions

    InSTALLATIOn 3�15�2 Position and dimensions i10 VSD SMART i16 VSD SMART Diameter of fittings 100 mm 120 mm 1� Air intake 2� Air delivery 3�15�3 Air outlet orientation 1� Default position Rotation 3�15�4 Connection to the system Avoid installing the unit near heat sources. The system needs a correct air flow in order to work effi- Preliminary warnings ciently.
  • Page 20 InSTALLATIOn Connection diagram Corrected curves Installation with vertical air flow direction 90° curves corrected Installation with horizontal air flow direction Correct air outlet ADAPTER PVC WITH CLAMP AIR GRILLE FLEXIBLE AIR DUCTING WITH FLEXIBLE AIR DUCTING WITH INSULATION INSULATION FLEXIBLE AIR DUCTING WITH AIR PLENUM INSULATION NO CHOKED CURVE NO AIR GRILL SMALL NO FLEXIBLE AIR HOSE WITHOUT INSULATION NO PLENUM WITHOUT...
  • Page 21: Electric Connections

    InSTALLATIOn 3�16 Electric connections The unit leaves the factory fully wired and only needs to be After connecting the interconnection and power cables, connected to the power supply and control panel. make sure that the cables are routed so that they do not apply excessive forces on the covers or electrical 3�16�1 Preliminary warnings panels.
  • Page 22: Electrical Panel

    InSTALLATIOn 3�16�2 Electrical panel 1� 2� Fixing bracket Electrical panel The electrical panel is supplied as standard installed on the – unscrew the 3 fixing screw unit. – remove the control panel In the case of limited installation space, the electrical cabi- – fix the electric panel in another area net can be detached during installation.
  • Page 23 InSTALLATIOn To access the connections: To make the connection: – undo the screws of the closing panel of the electric – insert the cables through the rubber seal panel – bring the power cord to the terminal block – remove the panel –...
  • Page 24 InSTALLATIOn notches Before wall installation: – Unhook the protruding notches on the back side of the control. – separate the base from the control – use the base of the control to trace the fixing point on the wall Base of the control Holes for the wall mounting Screws Hole for the passage of the electrical connections For the remote control wall mounting: –...
  • Page 25: Interface

    InSTALLATIOn CONTROL PANEL 4�1 Interface 4�1�1 Description Switched on for alarm indication The wall-mounted remote control is an electronic thermo- Cooling function on stat equipped with: • integrated WiFi module Heating function on • internal memory with data saving even in case of Remote control indication off shut-down or power outage The room temperature probe ensures an antifreeze...
  • Page 26: Set The Key Lock

    InSTALLATIOn Make sure that the remote control is connected to the Down key mains. Up key In case of a master switch on the power supply line, switch on the system by inserting the switch. Allows switching between heating and cooling functions To activate the device press the...
  • Page 27: Brightness Reduction

    InSTALLATIOn 4�2�9 Brightness reduction 4�2�11  R oomtemperatureprobeoffset adjustment To reduce the display brightness press the key for 5 seconds – To adjust the room temperature probe offset The text appearing on the display. from display off, press the key for about 5 sec- –...
  • Page 28: Maintenance

    MAInTEnAnCE MAINTENANCE Routine maintenance is essential to keep the device always efficient, safe and reliable over time. 5�1 Preliminary warnings Before each cleaning and maintenance intervention: Carrying out any technical or cleaning work before dis- – disconnect the device from the power mains by turn- connecting the unit from the power supply is forbidden.
  • Page 29: Troubleshooting

    TROUBLESHOOTInG TROUBLESHOOTING 6�1 Troubleshooting table If the conditioner blocks because of an alarm (see follow- ing table), please communicate to the assistance centre the code on the display to facilitate interventions. Alarm Alarm displayed on App Description Faulty room temperature probe Lack of communication between controller and Switch off and restart the unit.
  • Page 30: Limited Warranty

    Or visit our website: www.uflex.it and www.uflexusa.com ship or material, it will be repaired or replaced at the Uflex discretion. And then shipped back ex works. 7�1 Installation / Validation & Commissioning The Uflex Marine Air Conditioning Products must be in- tions this applies only for the first released representative stalled by authorized installers or the installation must be application. checked and approved by an authorised installer.
  • Page 31 nOTE...
  • Page 32 Uflex s.r.l Via Milite Ignoto, 8/A 16012 Busalla (GE) Italia tel. +39 (0) 10 9620 244/239 fax. +39 (0) 10 9620 333 www.uflex.com service@ultraflexgroup.it...

This manual is also suitable for:

Velair i16 vsd smart

Table of Contents