3. Other Alarm Visual and Audible Indicators

Operational Mode
Normal (standby)
Test (button press
when no alarm condi-
tion is present)
(Note: Test is very
loud, stand a few feet
away.)
Smoke or CO alarm
Memory (unit has
experienced a smoke
or CO alarm event, or
has detected 100ppm
CO or greater.)
Smoke alarm Hush®
Mode (SMaRT Hush®
CONTROL)
CO alarm reset
6
Visual Indications
Green LED blink approx
every 60 sec.
Red LED blinks in time
with alarm pattern.
Red LED blink every
16 sec.
Red LED blinks every
2 sec.
None
Audible Indications
• Single beep.
• 3 long beeps, voice "Fire!", 3 long
beeps, 4 quick beeps, Voice
"Warning, Carbon Monoxide," 4
quick beeps,
After button push, voice "Smoke
previously detected" or "Carbon
Monoxide previously detected."
After button push, voice "Hush
Mode Activated." Smoke alarm
pattern stops. (If there is too
much smoke to allow Hush®:
voice "Too Much Smoke,
cannot be Hushed" Smoke alarm
pattern continues.)
After button push: CO alarm
pattern stops.
Action/Note
Perform button press once
a week to verify proper
alarm operation.
NOTE: Alarm memory is
only retained for 24 hrs.
Push button to clear Alarm
Memory.
This feature is to be used
only when a known alarm
condition, such as smoke
from cooking, activates the
alarm.
Unit is confirming if CO is
present or if it experienced
a nuisance situation.
Re-alarm means danger.
Move to fresh air and call
911.