Download Print this page
Enerpac VE Series Repair Parts List Manual
Enerpac VE Series Repair Parts List Manual

Enerpac VE Series Repair Parts List Manual

Hide thumbs Also See for VE Series:

Advertisement

Quick Links

POWERFUL SOLUTIONS. GLOBAL FORCE.
RPS68.110-1
Contents:
Figure 1 - Electric Valve Assemblies, Models VE42TQ (115 VAC, 230 VAC and 24 VDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Figure 2 - Relief Valve, B-Port (Retract Circuit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 3 - Valve Mounting Components and Oil Return Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Figure 4 - Slider Valve Assembly, Electric Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 5 - Main Relief Valve Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 6 - Subassembly Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Relief Valve Adjustment Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8
Note: For relief valve adjustment instructions, refer to the procedures located after Figure 6 .
WARNING: Disconnect electrical power before beginning any maintenance or repairs .
Standard safety procedures are to be followed during disassembly and reassembly to minimize any possibility of injury .
04/2012
Repair Parts List &
Relief Valve Adjustment Instructions
Single Solenoid Models
For valve date codes beginning with "A" (electric 24 VDC models only).
For valve date codes beginning with "B" (all other electric models).
Valve Models:
VE42TQ-24VDC
VE42TQ-115VAC
VE42TQ-230VAC
1
VE-Series Valves
Page

Advertisement

loading
Need help?

Need help?

Do you have a question about the VE Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enerpac VE Series

  • Page 1 Repair Parts List & Relief Valve Adjustment Instructions VE-Series Valves POWERFUL SOLUTIONS. GLOBAL FORCE. Single Solenoid Models RPS68.110-1 04/2012 For valve date codes beginning with "A" (electric 24 VDC models only). For valve date codes beginning with "B" (all other electric models). Valve Models: VE42TQ-24VDC VE42TQ-115VAC VE42TQ-230VAC Contents: Page Figure 1 - Electric Valve Assemblies, Models VE42TQ (115 VAC, 230 VAC and 24 VDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 2 - Relief Valve, B-Port (Retract Circuit) .
  • Page 2 55˚ User-Adjustable Main Relief Valve (See Fig. 5) Slider Valve Assembly, Electric (See Fig. 4) Relief Valve O-Rings (See Fig. 5) B-Port Relief Valve (See Fig. 2) Notes: Torque to 32-39 ft-lbs [43-53 Nm], TO A LEAK Model information engraved on valve manifold. PROOF CONDITION AT OPERATING PRESSURE.
  • Page 3 Slider Valve, Electric, 230 VAC DC6792245 Plug, Flush (See Fig . 4) Slider Valve, Electric, 24 VDC Gasket, Copper ♦ G909167 G421026 Decal, Enerpac Nut, Acorn ♦ DC5625055 (See Fig . 5) Assembly, Relief Valve, Main Set Screw ♦ BF3110027F B1010028X...
  • Page 4 IMPORTANT: If replacing an old valve: DO NOT reinstall coil spring and check ball at oil inlet. These parts are not used with the single solenoid VA and VE valves. Oil Inlet (on pump) Figure 3, Valve Mounting Components and Oil Return Tube...
  • Page 5 SECTION A-A Notes: Torque to 50 in-lbs [5.6 Nm]. Torque to 100 in-lbs [11.2 Nm]. Torque to 150 in-lbs [16.9 Nm]. Figure 4, Slider Valve Assembly, Electric Models Repair Parts List for Figure 4 Item Part Number Qty. Description O-Ring, 7/32 x 11/32 ✲ B1004503 O-Ring, 5/16 x 7/16 URE ✲ B1011803 O-Ring, 2-5/8 x 2-3/4 ✲...
  • Page 6 Notes: Torque to 32-39 ft-lbs [43-53 Nm]. Lubricate O-Ring with grease before assembly. Torque to 10-12 ft-lbs [13-16 Nm]. See Figure 10 Figure 6 Notes: Apply Loctite 242, Torque to 10-12 ft-lbs [13-16 Nm]. Sectional View Lubricate with thin layer of grease before assembly.
  • Page 7 Relief Valve Adjustment Instructions VE-Series Valves POWERFUL SOLUTIONS. GLOBAL FORCE. Single Solenoid Models L2908_avdel_march30 2012 Rev. D 12/11 For valve date codes beginning with "A" (electric 24 VDC models only). For valve date codes beginning with "B" (all other electric models). 1.0 INTRODuCTION Note: Relief valve handle will rotate only about two-thirds of a full turn . When rotation stops, pull up on handle to disengage . Then, The VE-Series valve contains two relief valves, a user-adjustable reposition and re-engage handle to allow additional adjustment main relief valve, and a separate “B-Port”...
  • Page 8 French speaking African countries Applied Power Japan LTD KK ENERPAC SPAIN, S.L. African countries ENERPAC AFRICA ( PTY ) Ltd. Block V Unit 3, Regents Park Estate 391 ENERPAC Besshocho 85-7, Kita-ku, Avda. Los Frailes, 40 – Nave C & D Saitama-shi 331-0821, Japan Pol.