Troubleshooting

GR
Fault
‡ Motor does not start
TR
SLO
HR
‡ Motor does not run in
automatic mode
SK
‡ Reduced suction power
CZ
PL
H
RO
BG
RUS
EST
‡ No suction power during wet
LV
cleaning
‡ Voltage fluctuations
LT
AL
MK
SR
UK
20
Description
> Fuse in mains plug has blown.
> Overload protection switch has
tripped.
> Power tool is defective or not
connected properly.
> Suction power selected with
suction power control is to low.
> Hose diameter does not
correspond with switch
position.
> Clogged suction hose/nozzle.
> Seal/tank rim between the
upper section of the cleaner
and the dirt tank is dirty/
defective.
> Filter bag is full.
> Filter element is clogged.
> Tank is full (floater closes the
suction opening).
> Impedance of power supply is
too high.
107418007
Cause
Order no.
P-70219
P-70297
Remedy
Reset the fuse.
Switch off the vacuum cleaner
and allow it to cool for approx. 5
minutes. If it can not be started
again, contact the Makita
service department.
Check that the power tool
works or that the plug is
inserted correctly.
Set suction power in
accordance with section
"Suction power control".
Set correct switch position for
hose diameter.
Clean suction hose/nozzle.
Clean/replace seal.
See section "Replacing the
filter bag".
See section "Cleaning the filter
element" and "Replacing the
filter element".
Switch off the cleaner. Empty
the tank.
Use a suitable extension cord
(see section "Technical data").
Connect the cleaner to another
socket closer to the fuse box.
Voltage fluctuations over 7
% should not occur if the
impedance at the transfer point
is ≤ 0.15 Ω.