  • Page 1 Guidance Installation Manual Comm-Link Document Number C730-058-6820...
  • Page 2  No part of this document may be reproduced without Miura's express consent. All rights in the document are reserved by the Japanese copy right law.  No part of this document may be copied without Miura’s written permission in any way.
  • Page 3 Guidance Guidance This manual is written to describe installation of a Comm-Link/ER. Please read this manual carefully and follow the instruction. The following caution sign is used to tell you what parts of the manual you need to be careful for your safety.
  • Page 4: Table Of Contents

    Table of Contents Table of Contants Precautions ..............................1 Outside View Drawings ..........................2 Outside View Drawings .......................... 2 Moving ................................3 Dimensions ............................3 Moving Instruction..........................3 Compornents ............................3 Installation ..............................4 Installation Suggestions ......................... 4 Mounting ............................... 5 Wirings ................................
  • Page 5: Precautions

    14. The total length of the twisted-paired cables of the M-NET network must be less than 900 m. When the total length exceeds 900m you need to install additional option devices. Please consult your closest Miura office for further information.
  • Page 6: Outside View Drawings

    Comm-Link/ER Installation Manual 2 Outside View Drawings 2.1 Outside View Drawings Size (mm) Figure 2-1 Outside View Drawings...
  • Page 7: Moving

    Comm-Link/ER Installation Manual 3 Moving 3.1 Dimensions See the section 7: Specifications for the dimensions and weights. The transportation sizes are a little larger than the actual sizes since it is packed in a cardboard box. 3.2 Moving Instruction Please use a hand lift or carriage to protect the device from damage when you move it.
  • Page 8: Installation

    4 Installation 4.1 Installation Suggestions NOTE Please make sure that the Comm-Link/ER will be installed at a right place which meets the following requirement. It might cause a problem when it is not installed properly.  The device must be installed indoors. Please install the device at a place where doesn’t have a raining, snowing, or freezing risk.
  • Page 9: Mounting

    4.2 Mounting Please tightly install (4)-anchor bolts (pre-installed or hole-in-anchor bolts) in the wall on which you install the Comm-Link/ER cabinet. Please see the figure 4-1 for the locations and sizes of the anchor bolts. Pre-installed or Hole-in-anchor bolts 5/16”...
  • Page 10: Wirings

    5 Wirings 5.1 Cable Holes You should make cable holes at the bottom side of the Comm-Link/ER cabinet to install the power cables, ground cables, signal cables, and communication cables. Please use wiring protections such as cord bushings. 5.2 Main Power and Ground Wirings Please establish the power cable connection to the Comm-Link/ER cabinet.
  • Page 11: Signal Wirings

    (double swage type). NOTE Please use cord bushings which are certified by UL, CSA, or an European certificate organization such as TUV, VDE, or SEMKO) for the wiring inlet holes of the Comm-Link/ER cabinet to install the wires tight enough. ...
  • Page 12: Boiler Network Wirings

    Comm-Link/ER Installation Manual 5.4 Boiler Network Wirings As shown in the “Figure 5-3: Boiler Network Communication Cables” and “Figure 5-4: Twisted-Paired Cables to the Terminal Block”, please connect the boiler network communication cables (twisted-paired cables) from another M-NET device to the communication adaptor terminal block.
  • Page 13 N0, for instance. The shield wires of twisted-paired cables for either of the end network devices should be connected to the FC terminal. When the Comm-Link/ER is not one of the end network devices please remove the end resistor and connect the communication cables as well as others.
  • Page 14: Modbus Tcp Wirings

    Comm-Link/ER Installation Manual 5.5 Modbus TCP Wirings The communication cable to the Modbus TCP network needs to be installed to send the Miura boiler system data to the customer’s system. Please install the Ethernet cable of Modbus TCP to the PROFINET (LAN) connector port of the Micro controller with the “Figure 5-5 Ethernet Cable Connection”.
  • Page 15 Figure 5-6 Ethernet Cable Types NOTE You should use an Enhanced category 5 or higher, shielded straight cable (Cat5e STP) and the cable length between two devices always has to be within 100 m. Consult your closest Miura office when you have a question.
  • Page 16: Ipc Installation And Wirings

    Comm-Link/ER Installation Manual 6 IPC Installation and Wirings 6.1 IPC Installation Bracket Installation You can find two brackets in the shipped box for the IPC installation. Please install the brackets to the IPC cabinet using (6) - M3 x 6mm screw volts which will also be found in the box. The maximum screw depth in the box is 5mm.
  • Page 17 Comm-Link/ER Installation Manual IPC Installation You can find (4)-M4 screw bolts on the Comm-Link/ER cabinet inside. Please install the IPC by using those. (4)-M4 Screw Bolts Figure 6-3 IPC Installation...
  • Page 18: Ipc Wirings

    Comm-Link/ER Installation Manual 6.2 IPC Wirings COM1- Serial Cable Connection Please connect the serial cable with a D-sub 9 pin type connector (with COM1 sticker) to the COM1 serial connector port of the IPC (see Figure 6-4). COM4- Serial Cable Connection Please connect the serial cable with a D-sub 9 pin type connector (with COM4 sticker) to the COM4 serial connector port of the IPC (see Figure 6-4).
  • Page 19 Comm-Link/ER Installation Manual Keyboard and Mouse Connection Please connect the keyboard cable to the USB connector (see Figure 6-5). Then please connect the mouse connector to the keyboard (or the IPC directly). You can use the side cable hole for the USB cables.
  • Page 20 Comm-Link/ER Installation Manual Display Power Cable and Display Cable Connection Please connect the DVI-D cable shipped with the display to the connector port of the display as well as that of the IPC. You can use the side cable DVI-D Cable hole for the DVI-D cable.
  • Page 21 Comm-Link/ER Installation Manual Speaker Power Cable and Speaker Cable Connection Please connect the audio cable pin jack (light green) of the speaker to the audio adaptor (with a head phone picture) in the cabinet. Then please connect the USB cable of the audio adaptor to the USB connector port of the IPC.
  • Page 22: Specifications

    Comm-Link/ER Installation Manual 7 Specifications 1) Device Specification Device Name Comm-Link/ER [Miura Co., LTD.] Dimensions 700mm[W] × 250mm[D] × 1,200mm[H] Weight 80kg Power Supply AC120V Single Phase 60Hz Total Power Capacity 1.2kVA Required Condition Ambient Temperature 50 to 90 F (Operation)
  • Page 24 Document Number C730-058-6820 Consult Miura representative for any question about the product. October 17, 2014 Issue date (The initial print) Manufacturer Miura Co., LTD.