Invacare Medley Ergo User Manual
Hide thumbs Also See for Medley Ergo:
Table of Contents

Advertisement

Quick Links

This manual MUST be given to the user of the product.
BEFORE using this product, this manual MUST be read and saved
for future reference.
Invacare® Medley® Ergo
Medley Ergo, Medley Ergo Low
en Bed
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Medley Ergo and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Invacare Medley Ergo

  • Page 1 Invacare® Medley® Ergo Medley Ergo, Medley Ergo Low en Bed User Manual This manual MUST be given to the user of the product. BEFORE using this product, this manual MUST be read and saved for future reference.
  • Page 2 All rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted.
  • Page 3: Table Of Contents

    8 Troubleshooting ........24 Contents 8.1 Troubleshooting electrical system....24 9 Technical Data .
  • Page 4: General

    • Application environment 3; Long-term care in a Invacare reserves the right to alter product specifications medical area where medical supervision is required without further notice. and monitoring is provided if necessary and medical...
  • Page 5: Service Life

    Medical Device Regulation 2017/745 Class I. 1.6 Limitation of Liability This product features the UKCA mark, in compliance with Invacare accepts no liability for damage arising from: Part II UK MDR 2002 (as amended) Class I. • Non-compliance with the user manual We are continuously working towards ensuring that the •...
  • Page 6: Safety

    – Ensure all cables are routed and secured Invacare provider or qualified technician before properly. attempting to use this product. – Ensure there are no loops of excess cable –...
  • Page 7: Mattresses

    – Only use original accessories for the product in use. – Due to regional differences, refer to your local Invacare catalog or website for available WARNING! accessories or contact your local Invacare Risk of falling representative.
  • Page 8: Labels And Symbols On The Product

    If such use is necessary, the bed and the other equipment must be closely observed to verify European Conformity that they are operating normally. This bed can be used together with Invacare approved accessories and medical electrical equipment connected to the heart (intracardially) UK Conformity Assessed...
  • Page 9 Safety Transport and storage conditions Operation conditions Marks out the location of connection for means of potential equalization. (Not present on all versions of this product) Label on 3/4 length side rails Indicates areas with increased risk of squeezing feet on the lower sides of the bed ends near the castors.
  • Page 10: Setup

    – Check all parts for shipping damage before use. Hi/Lo Motor (height adjustment) – In case of damage, do not use the product and contact your Invacare provider for further Hand control (not shown in image) instructions. Side rails are not delivered in the main configuration.
  • Page 11: Assembling The Bed

    Setup 3.3 Assembling the bed 3.3.1 Attaching Labels 1. Untighten thumb screws on both sides. (Low version only) 1. Place the four foot squeezing warning labels (delivered separately) on the lower sides of the bed ends near 2. Push the inserts on the upper half of the mattress the castors.
  • Page 12: Wiring

    Invacare® Medley® Ergo 3. Manually raise the backrest and connect the loose actuator cable to its motor. The control box A is provided with a label with symbols showing where to connect the motor plugs: • Thigh section’s motor B.
  • Page 13: Installing Side Rails

    Setup 3.7 Installing side rails 7. Guide the Hi/Lo motor cables through the motor pipe pins. WARNING! Risk of personal damage There is a risk of entrapment or squeezing, while assembling or disassembling the side rail. – Pay attention to your fingers. –...
  • Page 14: Installing The Mattress Support Extension

    Invacare® Medley® Ergo The installation of Bella wooden side rail and Aria steel side rail is identical. Assembling the gliding system Push the attachment into the guide until it attaches with an audible click (=properly engaged in the lower position).
  • Page 15: Dismantle The Bed

    Setup 3.9 Dismantle the bed 5. Disconnect the cable from the backrest motor. 6. Separate the mattress support from the bed ends. 1. Remove the side rails and the lifting pole. 7. Divide the head and foot end of the mattress support. 2.
  • Page 16: Operating The Bed

    Invacare® Medley® Ergo Backrest section 4 Operating the bed 1. Up: press left side of the button (p). 2. Down: press right side of the button (q). 4.1 General Safety Information WARNING! Height adjustment Risk of personal injury and damage to property.
  • Page 17: Castors And Brakes

    Castors might make marks on different types of absorbing floor surfaces - such as untreated or badly treated floors. To prevent marks, Invacare® recommends to place a suitable kind of protection between the castors and the floor. 4.3.1 Castor brake 1.
  • Page 18: Lifting Pole

    Invacare® Medley® Ergo 4.5 Lifting pole 4.7 Emergency positions In case of a medical emergency, it might be required to WARNING! bring all or certain mattress support sections into a flattened Risk of injury position - e.g. a flattened back section for cardiopulmonary The bed can tip if the handle is used, while the resuscitation (CPR).
  • Page 19: Options

    – Use only original options and spare parts. Due to regional differences, refer to your local Spare parts lists and extra user manuals can be Invacare website or catalog for details about available ordered from Invacare. options or contact your Invacare provider.
  • Page 20 Invacare® Medley® Ergo 60128481-C...
  • Page 21: Maintenance

    6.4.1 Checklist - After relocation A service contract can be made in the countries, where Checkpoints Invacare has its own sales company. In certain countries Check that the inserts connecting the two mattress Invacare offers courses in service and maintenance of the support halves are fully inserted and locked.
  • Page 22: Cleaning And Disinfection

    The wooden side rails gliding system must not be – before using it for a new user. lubricated with oil - otherwise the wooden bars will move sluggishly. 6.5.3 Cleaning by Hand For ordering of correct oil, contact your Invacare provider. All components (excluding removable textiles) 60128481-C...
  • Page 23: After Use

    After Use 7.2 Reconditioning 7 After Use This product is suitable for reuse. To recondition the product for a new user, carry out the following actions: 7.1 Disposal • Inspection • Cleaning and disinfection Be environmentally responsible and recycle this product through your recycling facility at its end of life.
  • Page 24: Troubleshooting

    Invacare® Medley® Ergo 8 Troubleshooting 8.1 Troubleshooting electrical system Symptom Possible cause Remedy Mains are not connected Connect mains Mains indicator does not light up Fuse in the control unit is blown * Replace the control unit Control unit is defective...
  • Page 25: Technical Data

    166 – 207 cm Mattress Platform Steel (powder-coated) 15 – 55 cm 22 – 62 cm Bed Ends Steel (powder-coated) and MDF Medley Ergo Low Side Rails Steel (powder-coated) or Wood Height High Lifting Pole Steel (powder-coated), PP and POM 21 –...
  • Page 26: Electrical Data

    Invacare® Medley® Ergo Mattress support mounted in high position. The bed has no isolator (main switch). If the bed Mattress support mounted in low position. needs to be electrically disconnected, it has to be unplugged from the mains socket. 9.5 Electrical data 9.6 Environmental conditions...
  • Page 27: Electromagnetic Compatibility (Emc)

    Electromagnetic compatibility (EMC) 10 Electromagnetic compatibility (EMC) 10.1 General EMC information Medical Electrical Equipment needs to be installed and used according to the EMC information in this manual. This product has been tested and found to comply with EMC limits specified by IEC/EN 60601-1-2 for Class B equipment. Portable and mobile RF communications equipment can affect the operation of this product.
  • Page 28: Test Specifications For Immunity To Rf Wireless Communications Equipment

    Invacare® Medley® Ergo Immunity test Electromagnetic environment – guidance Test / Compliance level < 0% U for 0,5 cycle at Voltage dips, short Mains power quality should be that of a typical commercial or hospital 45° steps interruptions and environment. If the user of this product requires continued operation during...
  • Page 29 Electromagnetic compatibility (EMC) Test Frequency Service Maximum Immunity test Band (MHz) Modulation Distance (m) (MHz) power (W) level (V/m) GSM 1800; CDMA 1900; 1720 Pulse GSM 1900; 1845 1700 - 1990 modulation DECT; LTE Band 1970 217 Hz 1, 3, 4, 25; UMTS Bluetooth, WLAN, 802.11...
  • Page 30 Notes...
  • Page 31 Notes...
  • Page 32 United Kingdom & Ireland: Invacare Limited Pencoed Technology Park, Pencoed Bridgend CF35 5AQ Tel: (44) (0) 1656 776 200 uk@invacare.com www.invacare.co.uk Invacare Portugal, Lda Rua Estrada Velha 949 4465-784 Leça do Balio Portugal Invacare UK Operations Limited Unit 4, Pencoed Technology Park, Pencoed...

This manual is also suitable for:

Medley ergo low

Table of Contents