GE EntelliGuard G Application Manual page 46

Power circuit breaker
Hide thumbs Also See for EntelliGuard G:

Advertisement

Section 5. Catalog Numbering Guide
CSC = Coil Signaling Contact ST = Shunt Trip
Digit 13
Bell Alarm / Trip Annunciation
Bell Alarm / Trip Annunciation
Bell Alarm Contact (1NO/1NC) With Lockout
Mechanical Operations Counter
Bell Alarm Contact With Lockout and MOC
RTC Power Rated Contacts on SD
RTC Signal Rated (HiFi) Contacts on SD
RTC Signal Rated (HiFi) Contacts Through Trip Unit
Bell Alarm Contact With Lockout and RTC Power Rated
Contacts on SD
Bell Alarm Contact With Lockout and RTC Signal Rated
(HiFi) Contacts on SD
Bell Alarm Contact With Lockout and RTC Signal Rated
(HiFi) Through Trip Unit
Bell Alarm Contact With Lockout, MOC and RTC Power
Rated on SD
Bell Alarm Contact With Lockout, MOC and RTC Signal
Rated on SD
Bell Alarm Contact With Lockout, MOC and RTC Signal
Rated (HIFI) Through Trip Unit
MOC and RTC Power Rated on SD
MOC and RTC Signal Rated on SD
MOC and RTC Signal Rated (HIFI) Through Trip Unit
Blank/None
Abbreviations:
HiFi = High Fidelity
MOC = Mechanical Operations Counter
SD = Secondary Disconnewct
Digit 14
Key Interlock
Key Interlock (Breaker Mounted)
Castell Key Interlock
Kirk Key Interlock
Ronis Key Interlock
Profalux Key Interlock
Pushbutton Padlock Device
Castell Key Interlock and Push Button Padlock Device 1
Kirk Key Interlock and Push Button Padlock Device
Ronis Key Interlock and Push Button Padlock Device
Blank/None
NOTES:
This option provides factory installed interlocking devices for installation between separate
circuit breakers (baseplates and mechanism). This safeguard ensures that a circuit breaker
cannot be closed unless the dedicated key has been inserted and secured within the lock.
Locks and keys are NOT supplied by GE.
Digit 15
Future Use
Mechanical Interlocks
Blank/None DEFAULT
Mechanical Interlock - Type A 1
Mechanical Interlock - Type B 2
Mechanical Interlock - Type C 3
Mechanical Interlock - Type D 4
Some installations use multiple power sources that are required to supply energy simulta-
neously, alternately, or, in a specified sequence. EntelliGuard G Circuit Breakers can be used
to interconnect these sources and be electrically and mechanically interlocked to provide
the necessary transition and protection. Mechanical Interlocks are available for fixed and
draw out circuit breakers. The interlocks enable directly interlocking breakers that are
mounted side by side or in vertical stacks. The interlocks consist of two components: (A)
The factory-installed bracket fitted to the breaker (fixed breakers) or the cassette (drawout
breakers), and (B) The field-installable interconnecting cables available in lengths of 1.0, 1.6, 2.0,
2.5, 3.0, 3.5 and 4.0 meters (ordered separately). Refer to Section 4 for interlocking schemes.
44
Courtesy of NationalSwitchgear.com
Code
A
B
C
1
2
3
D
E
F
G
H
J
K
L
M
X
Code
C
K
R
P
L
2
3
X
Code
X
Digit 16 & 17
Overcurrent Protection Package
Type
Package
LSI (S, switchable) (I, switchable ANSI only)
LSIG (S, switchable) (I, switchable ANSI only)
LSIGA (S, switchable) (I, switchable ANSI only) L5
LSIC (S, switchable) (I, switchable ANSI only)
LSICA (S, switchable) (I, switchable ANSI only) L7
LSIGDA* (S, G, A all switchable) (I, switchable
ANSI only)
LSIGCDA* (S, G, C, A all switchable) (I, switchable
ANSI only)
LSH (S, switchable) (H, switchable ANSI only) LC
Entelliguard G
LSHG (S, switchable) (H, switchable ANSI only)
ANSI/UL
LSHGA (S, switchable) (H, switchable ANSI only) LE
LSHC (S, switchable) (H, switchable ANSI only) LF
LSHCA (S, switchable) (H, switchable ANSI only) LG
LSHGDA* (S, G, A all switchable) (H, switchable
ANSI only)
LSHGCDA* (S, G, C, A all switchable) (H,
switchable ANSI only)
G (PB II Switch and EntelliGuard Switch GF
Relay only, FUTURE)
GA (PB II Switch and EntelliGuard Switch GF
Relay only, FUTURE)
JSI (S, switchable) (I, switchable ANSI only)
JSIG (S, switchable) (I, switchable ANSI only)
JSIGA (S, switchable) (I, switchable ANSI only) J5
JSIC (S, switchable) (I, switchable ANSI only)
JSICA (S, switchable) (I, switchable ANSI only) J7
JSIGDA* (S, G, A all switchable) (I, switchable
ANSI only)
JSIGCDA* (S, G, C, A all switchable) (I, switchable
Entelliguard G
ANSI only)
ANSI/UL with
JSH (S, switchable) (H, switchable ANSI only) JC
Fuse Settings
JSHG (S, switchable) (H, switchable ANSI only) JD
JSHGA (S, switchable) (H, switchable ANSI only) JE
JSHC (S, switchable) (H, switchable ANSI only) JF
JSHCA (S, switchable) (H, switchable ANSI only) JG
JSHGDA* (S, G, A all switchable) (H, switchable
ANSI only)
JSHGCDA* (S, G, C, A all switchable) (H,
switchable ANSI only)
*Function combination is NOT UL Listed
NOTES:
OC and protection definitions:
2
L = Long Time (I
T, all trip units)
J = Long Time Protection (L) + Fuse Settings (Selectable I
S = Short Time (switchable if Instantaneous (I) protection is enabled)
I = Standard Range Adjustable Instantaneous, (IOC, 2x-15x)
H = Extended Range Adjustable Instantaneous (IOC, 2x-30x)
G = Ground Fault Protection (GFP, 3-wire or 4-wire, internal summing)
C = External CT for ground fault detection (input from external summing CTs, used for
multiple source ground fault detection)
D = Ground Fault Protection, or GF/Earth CT internal summation or external CT,
Defeatable/Switchable. Not UL listed
A = Ground Fault, or GF/Earth CT internal summation or external CT, Alarm only
Refer to Entelliguard Trip Unit Application Guide for detailed descriptions and configuration.
Code
L3
L4
L6
L8
L9
LD
LH
LK
LW
LY
J3
J4
J6
J8
J9
JH
JK
2
T or Fuse Setting)

Hide quick links: