Immergas EOLO Star Export Manual page 8

Compact wall-hung instantaneous with sealed-room boilers
Table of Contents

Advertisement

Technical documentation
Technical documentation
HYDRAULIC CIRCUIT
HOT WATER CIRCUIT
- OPERATION
Running the hot water results in transit of cold water inside the flow switch (3) and consequent
closing of the electrical contact coupled to this (see electrical circuit).
As a result, the regulation circuit begins an operating stage with hot-water priority that starts the
burner and, if a central heating request is under way, switches off the boiler pump.
This way, the heat in the fumes produced by combustion is absorbed by the copper blades of the
bithermal exchanger (1) and transferred to the heating circuit water which, in turn, transfers it to the
cold water circuit inside the "cross-shaped" hot-water circuit pipes (2).
- HOT WATER FLOW SWITCH
Whenever hot water is run at a rate of at least 2.5 l/min
and with a dynamic pressure of 0.26 bar, the flow
switch (2) enables the boiler to operate in hot-water
mode.
This is done by means of a magnet which, by lifting
when invested by the cold water flow, moves near to an
electrical contact (reed relay) and causes movement by
means of a magnetic effect.
6