Immergas EOLO Star Export Manual page 28

Compact wall-hung instantaneous with sealed-room boilers
Table of Contents

Advertisement

Technical documentation
Nominal heating capacity
Minimum heating capacity
Nominal heat output (useful)
Minimum heat output (useful)
Working thermal performance at rated power
Working thermal performance at 30% load of rated power
Loss of heat at shell with burner off / on
Loss of heat at stack with burner off / on
Diameter of gas nozzle (G20)
Gas pressure (G20)
Diameter of gas nozzle (G30)
Gas pressure (G30)
Diameter of gas nozzle (G31)
Gas pressure (G31)
Max operating pressure of heating circuit
Max operating pressure of heating circuit
Adjustable heating pressure
Total volume of expansion vessel
Expansion vessel preloading
Amount of water in boiler
Available head capacity 1000 l/h
Working thermal power for the production of hot water
Adjustable hot water temperature
Flow limiting device
Hot water circuit minimum dynamic pressure
Max hot water circuit operating pressure
Minimum hot water supply
Continuous service supply capacity with ∆T 30ºC
Specific capacity with ∆T 30ºC
Minimum pressure for flow limiting device rated capacity
Full boiler weight
Empty boiler weight
Power connection
Rated input
Installed power
Power absorbed by circulator
Power absorbed by fan
Appliance electrical system cutout
STES ed 07/01
EOLO Star TECHNICAL DATA
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
%
%
mm
mbar (mm H
2
mm
mbar (mm H
2
mm
mbar (mm H
2
bar
ºC
ºC
l
bar
l
kPa (m H
O)
2
kW (Kcal/h)
ºC
l/min
bar
bar
l/min
l/min
l/min
bar
kg
kg
V / Hz
A
W
W
W
-----
26
Technical documentation
25.7 (22124)
11.2 (9674)
23.3 (20000)
9.3 (8000)
90.4
88.5
0.53 / 2.1
0.02 / 7.5
1.30
O)
20 (204)
0.77
O)
29 (296)
0.77
O)
37 (377)
3
90
35 - 80
6
0.8
3.5
23.03 (2.35)
23.3 (20000)
35 - 55
8
0.26
10
2.5
11.1
10.7
1.0
38
34
230 / 50
0.8
140
63
46
IPX4D
EOLO STAR

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eolo star

Table of Contents