Tools / 安装工具
Phillips/Flat-head
Socket wrench set
Adjustable wrench
Hammer drill
screwdriver
活动扳手
套筒扳手
十字 / 一字螺丝刀
Wire stripper
COAX crimping tool
Diagonal pliers
Hydraulic pliers
剥线钳
液压钳
压线钳
Measuring tape
Protective gloves
Insulated gloves
Heat gun
卷尺
防护手套
绝缘手套
Short-handle Phillips
Electroprobe
Step ladder (2 m)
Electrician's knife
screwdriver (85 mm)
电笔
人字梯(2m)
电工刀
短柄十字螺丝刀(85mm)
UPS PDC Layout / 结构示意图
NOTE / 说明
Cabinet dimensions (H x W x D): 2000 mm x 800 mm x 850 mm
机柜尺寸(高×宽×深): 2000mm×800mm×850mm
T5-3P
Input circuit breaker
输入空开
Surge protective
device (SPD) and
SPD circuit breakers
防雷器及防雷空开
FS
QFS
QF1
QF2
T3-3P
T3-3P
T3-3P
T E S T
T E S T
T E S T
QF3
QF4
QF5
Output circuit breakers
输出空开
T3-3P
T3-3P
T E S T
T E S T
QF6
QF7
NOTE / 说明
The positions and number of circuit breakers in the figure are for reference only. The actual product prevails.
空开位置和数量仅为示意,请以实物为准。
2
Installing an UPS PDC / 安装UPS配电柜
Checking Before Installation / 安装前检查
Open the packing case, and check that all components listed in the packing list are intact. Ensure that all components
are available before cleaning up the package materials. If components or fittings are damaged during transportation or
do not comply with the order contract, make records onsite and contact the local Huawei regional office or
representative office immediately.
Claw hammer
羊角锤
打开包装箱,根据装箱清单检查设备的配件是否齐全、是否在运输过程中损坏。清除包装材料之前,要确保所有配件都已
冲击钻
找到。如设备和配件在运输中损坏或与订货合同不符,应及时现场记录,并与华为公司当地分公司或办事处代表联系。
Installing the Cabinet / 安装机柜
Move the cabinet from the wood pallet to the ground.
将机柜从木栈板移动至地面。
Level
Plan the cabinet installation position based on the following figure.
水平尺
斜口钳
参考下图规划机柜安装位置。
Unit: mm
单位:mm
热风枪
Drill holes using a hammer drill and install expansion bolts.
用冲击钻钻孔并安装膨胀螺栓。
Align the cabinet with mounting holes, and use a level to level the cabinet by adjusting the leveling feet.
将机柜对齐安装孔,配合水平尺调节地脚螺栓使机柜水平。
Insert bolts into the mounting holes and partially tighten the bolts.
将螺栓插入安装孔并预紧固。
Output circuit breakers
输出空开
NOTE / 说明
1. Wrench a leveling foot clockwise to elevate the cabinet, or wrench an anchor bolt counterclockwise to lower the
cabinet. The adjustable height ranges from 0 mm to 8 mm.
顺时针方向将机柜调高,逆时针方向调低。地脚调节范围:0mm~8mm。
2. Adjust four leveling feet to avoid damage to the cabinet. Adjusting only one leveling foot may slant the cabinet.
机柜调平过程中,不要只调节一方地脚的高度,尽量四方地脚协调调节,以免机柜倾斜造成机柜损坏。
Tighten the bolts in diagonal order.
按对角线顺序交叉紧固螺栓。
600
730
850
800
Bottom view of the UPS PDC / UPS配电柜底部视图
NOTE / 说明
If the cabinet is installed on a support, skip
steps 2 and 3.
如果机柜安装在支架上,步骤2、3可省略。
NOTE / 说明
The following table lists the tightening
torque of different bolts.
各螺栓紧固扭矩说明如下表所示。
Bolts /
Recommended torque
螺栓
/ 推荐扭矩 (N· m)
M8
13
M10
27
M12
47
M16
120
3
Installing Input and Output Cables / 安装输入输出线缆
Input cables / 输入接线
Cables are routed in and out from the bottom.
进出线方式为:下进下出。
T5-4P
T3-3P
Left view of the UPS PDC / UPS配电柜左视图
Output cables / 输出接线
Left view of the UPS PDC / UPS配电柜左视图
4
NOTE / 说明
Maintenance bypass
维修旁路

Advertisement