01
Close driver door. Re-open driver door to wake
up data bus.
02
Press Unlock on OEM remote. If the vehicle is
not equipped with an OEM remote, press the
module programming button.
03
Wait, LED will fl ash GREEN once [1x]. If LED
does not fl ash GREEN, press Unlock on OEM
remote again.
04
Turn key to ON position.
ACC
ON
START
OFF
05
Wait, LED will turn solid RED.
06
Turn key to OFF position.
ACC
ON
START
OFF
Patent No. US 8,856,780 CA 2759622
Automotive Data Solutions Inc. © 2022
MODULE PROGRAMMING PROCEDURE - 1 OF 2
07
Remove key.
ACC
ON
OFF
START
08
Insert key into ignition.
ACC
ON
START
OFF
09
Turn key to ON position.
ACC
ON
START
OFF
10
Wait, LED will fl ash GREEN.
11
Turn key to OFF position.
ACC
ON
START
OFF
12
WARNING: Disconnect power last. Disconnect
module from vehicle.
FLCI-CH(RS)-CH8-[FLRSCH7]-EN
13
Connect module to computer and proceed
with extended programming.
14
WARNING: Do not press module programming
button. Connect power fi rst. Connect module
to vehicle.
15
Turn key to ON position.
ACC
ON
START
OFF
16
Wait, LED will turn solid GREEN for 2 seconds.
17
Turn key to OFF position.
ACC
ON
START
OFF
18
Turn key to START position.
ACC
ON
START
OFF
PAGE 11 OF 22
• 20221216
DOC.: #81143
www.flashlogic.com