ONLY follow the below changes if the
NOTE
door is leaking.
DOOR APERTURE ALIGNMENT
1 Level the bath from the highest elevation point
on the floor.
If the floor is sloping or bowed in
any way, work from the highest
elevation point. Use the bath panels
as a guide to the height.
FIG. 14
A
2 Use a spirit level on all rims of the bath to verify
the product is completely level� Ensure all bath
feet are touching and secured to the ground�
3 Using a straight edge or spirit level and with the
door open hold this against the front flange see
FIG. 14�
4 Ensure plane A and B are level� If not this may
lead to leaking� Use the bath foot under the
door lock to make fine adjustments until
A and B are in-line�
5 W hen this is correctly aligned refill the bath
and check�