cNODE Micro Instruction Manual
Turning on the TTC
Before deployment, it is recommended to test the transponder with the Test and
Configuration unit (TTC) to make sure the transponder is fully operational.
Procedure
1
Open the suitcase.
Push the button in the middle of the fastener to open it.
2
Turn on the main power switch to start the program.
This takes approximately 1.5 minutes.
Acoustic test
Test the transponder acoustics to make sure it is functioning correctly..
Procedure
1
Set
TTC Power
to confirm your selection.
Set
2
Connect the test transducer cable to the upper right connector.
3
Place the test transducer face to face with the transponder transducer.
4
Select the
Acoustic test
5
Type in the serial number, if necessary.
6
Type in the transponder channel number, if necessary.
7
Tap
.
Interrogate
8
A green indicator will flash on the display if there is acoustic contact with the
transponder.
9
Tap
Interrogate
Transponder channels
All transponders have the default channel numbers on the label.
cNODE Micro only operates in Cymbal mode and uses the channels M01 - M56 for
SSBL and M57 - M62 for LBL interrogation. Channels such as B12 are not supported,
as they are for FSK use.
16
by using the left/right arrows to select the power level and tap
tab.
again to stop the acoustic test.
426351/C
Need help?
Do you have a question about the cNODE Micro and is the answer not in the manual?