Download Print this page

Right Display - PrimeWeld MIG285 Operation Instructions Manual

Advertisement

MIG/MAG/FLUX Mode Advanced Features Menu map
Left Display
Advanced Menu-MIG
Mode
PROC / ESS
WIRE / DIAM
PRE- / FLOW
POST / FLOW
Run / IN
BURN / BACK
WIRE / SHRP
SPOT
SPOT / TIME
STCH
STCH / TIME
DWEL / TIME
WFS / UNIT
FACT / DFLT
HR
Press Advanced Button for 3s
to Exit to Welding Mode
Advanced Features Selection
NOTE: SPOT TIME and STCH TIME and DWEL/TIME are only active
when SPOT or STCH are "ON".
Left
Display
Function
MIG Operator
PROC/ESS
Controls
Wire Diameter
WIRE/DIAM
Pre Flow
PRE- /FlOW
Post Flow
POST/FLOW
Run In
RUN/IN

Right Display

Advanced Menu-MIG
Options or Range
C25/C100/FLUX/ALUX
0.024/0.030/0.035/0.045
0.0-2.0 S
0.0-10.0 S
30-150%
0.00-1.00 S
ON OFF
ON OFF
0.1-20.0 S
ON OFF
0.2-4.0 S
0.1-1.0 S
MPM IPM
NO YES
0.0-9999.9
Press Advanced Button for 3s
to Exit to Welding Mode
Right Knob Selection
Right
Display
Limits
Comments
(Factory Default
Values)
C25
C25/C100/
C25=75%Ar+25%CO2
FLUX/ALUM
C100=100%CO2
FLUX=No Gas,Use the cored self-protecting
wire.
ALUM=100%Ar,Use the aluminum wire. Adjust
the parametes by selected Shielding gas.
0.030
0.024/0.030/
Adjust the parametes by selected wire diameter.
0.035/0.045
Shielding gas flows for the time specifed before
0.1
0.0-2.0S
an arc is initiated.
Shielding gas flows for the time specifed after
1.0
0.0-10.0S
an arc has extinguished.
30
30-150%
Wirespeed runs as a percentage of preset
wirespeed.