Installation
The product must be installed and maintained by
a suitably qualified professional in compliance with
latest building/construction and/or electrical regu-
lations and relevant legislation.
Attention: Do not open luminaire while mains
supply is switched on.
Notice: If the luminaire is modified by anybody
other than the original manufacturer, then the
warranty will no longer be valid and shall become
the full responsibility of the modifying person/
organisation. Claims based on defects attributable
to improper installation and/or application, and the
consequences thereof, are excluded.
Installation Procedure
1) Switch off the mains electrical supply.
In case of component failure, LED replacement
due to abnormal circumstances or at end of life,
replacement must be carried out by a suitably qua-
lified and trained professional.
In case of questions please contact our technical
hotline: +1 724 742 0030 (from Monday - Friday
from 08.00 until 16.00 hours).
Maintenance
Apart from cleaning the product's exterior surfaces,
no special maintenance work is required. Do not
use high-pressure cleaners.
Protect our environment: Discard used LEDs in
compliance with the most recent environmental
legislation.
2) Remove cover A by releasing the four screws B.
3) Check that rating shown on luminaire label con-
forms with mains electrical supply.
4) Determine positions for two fixing screws C.
Drill relevant holes D and insert wall plugs E.
Make sure not to damage any electric cable,
water pipe or other devices while drilling holes.
Fixture is intended to be mounted over a UL lis-
ted junction box (not supplied by WE-EF), use
provided wall plate to cover boxes larger than
the outer dimensions of the luminaire.
5) Feed the mains supply cable F (and the second
cable G for through wiring, if required), through
the through hole at the rear of the housing
while setting and fixing luminaire position.
To fix the luminaire, pierce through the nylon
plug N with screws C, and tighten (Fig. 1).
Attention: The nylon plugs N must remain in
position to provide sealing.
6) Remove gear tray and connect mains supply
leads to respective terminals in terminal block I
(N = Neutral, L1 = Phase,
= Earthing).
7) Reposition the cover A and secure in position
by evenly tightening the screws B.