Installation Information

INSTALLATION CONSIDERATIONS

This section uses some of the information in the ICBWS Series Installation Guide to address common installation
issues seen by Service Technicians. Improper installation, though not a valid service issue, has the potential to lead
to a call for service. Installation related complaints could include, but are not limited to: Unit leveling, unit move-
ment, door misalignment, improper door and drawer sealing, internal frost or condensation, exterior condensation,
warm compartment temperatures, etc.
The model ICBWS-30 is built on the ICBBI series platform, thus it has the following design alternatives: framed,
overlay and stainless steel models. The overlay design has two possible installation applications - standard overlay
and flush inset. Each of these design options has specific installation requirements, which means it is vital that the
unit match the planning and space needs.
NOTE:
If additional installation information is needed, refer to the complete Installation Guide, or contact the Sub-
Zero Customer Service Department.
Tools and Materials Required
The following is a list of tools and materials that will assist in a proper installation.
• Phillips screwdriver set
• Slotted screwdriver set
• 6-Lobe, Torx type drive screwdriver set
• 4' (1.2 m) of 1/4" copper tubing and saddle
• Level - 2' (.6 m) and 4' (1.2 m) recommended
• Appliance Dolly able to support 700 lbs (317 kg) and adequate manpower to handle the weight of the unit
• Various sized pliers
• Wrench set
• Allen wrench set
• 5/16" hex bolt nut driver
• Crescent wrenches
• Cordless drill and assorted drill bits
• Masonite, plywood, 1/8" pressed fiberboard, cardboard or other suitable material to protect finished flooring
• Appropriate materials to cover and protect the home and its furnishings during installation
Site Preparation
The finished rough opening where the ICBWS Series unit is to be installed must be properly prepared. Refer to the
Finished Rough Opening Specifications on the following pages. The specifications for the framed, overlay and stain-
less steel applications are identical. The Finished Rough Opening Specifications are different for the flush inset
application, whether using custom panels or Sub-Zero accessory stainless flush inset panels. Make sure that the
rough opening dimensions, door swing clearance and electrical service are correct for the model being installed.
If installing two ICBWS-30 units or an ICBWS-30 and an ICBBI unit side by side in the framed, overlay or stainless
steel application, a separating filler strip is recommended. Add the filler strip width to the finished rough opening
dimension, and ALWAYS complete the installation with the Anchoring Kit components.
For installation of two ICBWS-30 units or an ICBWS-30 and a Built-In unit side by side in the flush inset application,
a dual installation kit will be necessary.
IMPORTANT NOTE:
ICBWS-30 and ICBBI Series units installed side by side in the flush inset application cannot
use the standard Sub-Zero accessory overlay panels, and must have opposing hinges.
IMPORTANT NOTE:
To operate properly, the door must open a minimum of ninety (90) degrees. Use a minimum 3"
(76 mm) filler in corner installations to assure a ninety (90) degree door opening. Allow enough clearance in front of
the unit for full door swing.
IMPORTANT NOTE:
Make sure the floor under the unit is level with the surrounding finished floor.
#7013455 - Revision A - April, 2009
International W
ine Storage
International W
ine Storage
2-2
Series
Series
(ICBWS)
(ICBWS)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WOLF ICB WS Series and is the answer not in the manual?

Table of Contents