Page 2
Dear Client & User, Firstly, thanks for purchasing and using our product. All the information and guidelines of this user’s manual comply with certain applicable regulations, which come out from our long-term accumulated knowledge and experience as well as current project development situations.
Page 3
Warning ◆ Any self-modification, wrong installation, adjustment or maintenance can lead to property loss or casualty. Please contact the manufacturer for any adjustment or maintenance, and have the work done by a trained & qualified person. ◆ For your safety sake, please keep the machine away from any liquid, gas or other object, which is flammable or explosive.
2. Structure Schematic Diagram 2.1 Structure Schematic Diagram: REB-02 2.2 Structural & Functional Features: Stainless steel body, grill surface which is enameled and non-sticky, easy to clean. The grill is convenient to lift up and down.
3. Basic Features & Parameters Model REB-02 Dimension(mm) 885×550×587 Thermal Power(kW) 11.5/39238 Pressure (Pa) 2800 Consumption 0.93 (Kg/h) Gas Type Pressure (Pa) 2000 Consumption 1.11 (M³ /h) Gas Inlet Size Rc 1/2" Weight(kg) 4. Precautions & Recommendations 4.1 Transportation and Storage During transportation, the machine should be carefully handled and do not put it upside down to prevent from damaging to the shell and inside.
Page 7
5. The appliance should be installed separately or assembled with other devices in accordance with provisions. 6. The appliance is not suitable for built-in installation. 7. The appliance should keep a minimum clearance of 10cm away from non-combustible objects (e.g. walls, windows etc) on both sides, and 20cm at its back. Do not install the appliance on flammable floor or materials.
6. This product is a commercial machine that needs to be operated by trained personnel, not applicable for household use. 7. This product is only for commercial use, not suitable for other uses, or it may cause danger. 8. Do not dismantle or self-modify the appliance. Dismantlement and self-modification may cause casualty.
6. Routine Inspection It is necessary to check the machine daily. Check the machine regularly can avoid serious accident happens. Stop using if user feels that there are some problems in the circuit or machine. Check the situation of the machine before or after using every day. Before using: Whether the machine is tilted? Whether the control panel is damaged? During using: Whether there is strange odor or vibration noise?
8. Failure Analysis & Trouble Shooting Symptoms Causes Solutions Plug or plug cord of igniter is damaged. Replace relevant fittings. Pressure in gas pipeline is Regulate the reducing valve not enough. or contact the gas supplier. The pilot nozzle is blocked. The pilot flame cannot be Unblock the nozzle.