Benchmark Scientific SB-12L Operation Manual

Benchmark Scientific SB-12L Operation Manual

Shaking water bath

Advertisement

Quick Links

Operations Manual
Part Number: SB0012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SB-12L and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Benchmark Scientific SB-12L

  • Page 1 Operations Manual Part Number: SB0012...
  • Page 2: General Information And Precautions

    Only use the power cable that was included with the SB-12L shaking water bath. Use of other cables may cause damage to the instrument or electrical fire. Please contact Benchmark Scientific if a replacement is required.
  • Page 3 Do not place instrument in direct sunlight or an overly warm location. Recommended operating temperature is 20°C to 30°C. Do not use instrument with flammable substances. Install on flat, even surface. Failure to do so may affect the performance of the instrument. Benchmark Scientific SB-12L Shaking Water Bath V.1 3/11...
  • Page 4 Please clean silicone seal surrounding the heating chamber regularly with a damp cloth to prevent corrosion. Failure to do so may cause damage to the seal and affect the performance of the instrument. Benchmark Scientific SB-12L Shaking Water Bath V.1 4/11...
  • Page 5: Features And Specifications

    An advanced micro-processer confirms and maintains temperature setting and shake speed while unit is in operation. ● Brushless DC motor provides low noise and no vibration. ● LED indicates temperature, speed, time and state of power failure. Benchmark Scientific SB-12L Shaking Water Bath V.1 5/11...
  • Page 6: Specifications

    Button for storing RPM and TIME UP, DOWN Button for adjusting RPM and TIME value START/STOP Button for starting and stopping HEAT PILOT LAMP Display to show heating TEMP. SET Button for input temperature Benchmark Scientific SB-12L Shaking Water Bath V.1 6/11...
  • Page 7: Operation

    (located on the right of the unit) to the on position. * The SB-12L will begin to heat approximately 30 seconds after the unit is switched on. Never operate the water bath when the water level is not above the minimum marking.
  • Page 8 * The time set point range is a maximum of 47 hr 59 min. *The SB-12L can be used continually by setting the time to 00:00:00. tEnd will be displayed when unit is set in continuous mode, however, shaking will continue until operation is ended by user.
  • Page 9 If temperature control is not needed, set the temperature below ambient. Never operate the water bath when the water level is not above the minimum marking. Failure to do so may result in damage to the heater. Benchmark Scientific SB-12L Shaking Water Bath V.1 9/11...
  • Page 10: Warning Messages

    - The instrument has completed a set time cycle. 4) This message may be marked when: - There is a power failure during operation. - Solution : Press start when power is restored and re-enter desired settings.. Benchmark Scientific SB-12L Shaking Water Bath V.1 10/11...
  • Page 11: Warranty

    (3) Check the fuse. Warranty The SB-12L includes a two year warranty from the purchase date. Benchmark Scientific reserves the right to repair or replace the unit at its sole discretion. Any disassembly or evident misuse of the instrument will void all warranty.

This manual is also suitable for:

Sb0012

Table of Contents