Inspection Plan For Recurring Inspections Of The H-50.2 Fall-Arrest System - Hailo H-50.2 Manual

Hide thumbs Also See for H-50.2:
Table of Contents

Advertisement

Inspection and maintenance
8.2

Inspection plan for recurring inspections of the H-50.2 fall-arrest system

1.
Rail attachment
2.
Surfaces of fall protection rails
3.
Attachment of the fall protection rails
Interval/overhang
4.
Rail connectors (including flexible rail
connector/compensation piece, if in-
stalled)
5.
Rail joint (transitions)
6.
End stops
7.
Barrier for non-approved fall arrest-
ers (if installed)
8.
Access aid (if installed)
9.
Screw connections
10. Original marking
11. Functional test
12. Documentation
Technical condition, positioning in the middle of the access
ladder, firmly secured
Technical condition
Attachment interval
Hailo access ladder = ≤ 1,400 mm
Attachment interval
access ladder already installed = ≤ 1,120 mm
Overhang at the top/bottom rung
= min. 80 mm, max. 140 mm
Rail attachment at the beginning and end of a ladder sec-
tion
Technical condition, firmly secured
Distance between rails: max. 4 mm
Rail attachment before and after each rail joint
Attachment (secure positioning), technical condition, firmly
secured, installed on each entry and exit point
Attachment (positioning) and safety function
Technical condition (corrosion), firmly secured,
function of end stop at coupling,
function of lever (engagement and release)
Technical condition, firmly secured
All markings present and easy to read?
Use with Hailo PARTNER H-50.2 fall arrester
Inspection correct and fully documented?
Information brochure · H-50.2 system components
V02R00 · 1134319 · 2022-11
48
Inspection
Date (month/year)
Result

Advertisement

Table of Contents
loading

Table of Contents