B-9

AUXILIARY POWER

• 115VAC, 42VAC and 24VAC power is available
from the two 14-pin amphenols on the rear of the
unit. These supplies are intended to supply power
for auxiliary equipment like wire feeders and the TIG
Module.
• 115VAC supply is rated at 2 amps and is protected
by a 2.5 amp breaker located by the amphenol.
• 42 VAC supply is rated at 5.5 amps and is protected
by a 10 amp breaker located by the amphenol.
• 24 VAC supply is rated at 5.5 amps and is protected
by a 10 amp breaker located by the amphenol.

LIMITATIONS

• The EX350i is not recommended for processes
other than those listed.
• The EX350i can only be used with the recommend-
ed equipment and options.

RECOMMENDED PROCESSES

Properly equipped, the EX350i supports GMAW,
FCAW, SMAW, GMAW-P, GTAW and CAC-A
processes for a variety of materials, including mild
steel, stainless steel, cored wires, and aluminum.