5 TROUBLESHOOTING GUIDE
Refer to WIRING CONNECTION DIAGRAM.
< TROUBLE >
Hot air or cool air is
not emitted at "1" , "2"
or "3" position.
< CHECK >
Check continuity of power cord.
Check continuity between "1' and "4" of main
switch at 1 position.
Check continuity between "1" and "4"
between "2" and "4" of main switch at 2 position.
Check continuity between "1" and "4"
between "2" and "4" between "3" and "5" of main
switch at 3 position
Check the resistance of heater coil between
"2" and "5" of the Main switch at "0" or "1"
positions. The value should be as follows:
220~240V
:approx. 47.0Ω
110V
:approx. 10.3Ω
Check the resistance of voltage dropping
resistor between end of tinplate of voltage
dropping resistor (at lead wire gray for 110V, at
hard lead wire white for 220V-240V) in heater
block and "5" of main switch at "0" or "1"
position.
The value should be as follows:
220~240V
:approx. 528Ω
110V
:approx. 215Ω
Check if motor rotates when adding DC24V
to motor terminal.
Check the continuity of diode (D)
OK
OK
OK
OK
< REMEDY >
Replace power cord.
NO
Replace main switch.
NO
Replace heater block.
NO
Replace motor.
NO
Replace heater block.
NO

Advertisement