Crane BARNES EHV512 Series Installation Manual

Crane BARNES EHV512 Series Installation Manual

Submersible effl uent pump
Hide thumbs Also See for BARNES EHV512 Series:

Advertisement

Quick Links

IMPORTANT!
Read all instructions in this manual before operating pump.
As a result of Crane Pumps & Systems, Inc., constant product improvement program,
product changes may occur. As such Crane Pumps & Systems reserves the right to
change product without prior written notifi cation.
A Crane Co. Company
420 Third Street
Piqua, Ohio 45356
Phone: (937) 778-8947
Fax: (937) 773-7157
www.cranepumps.com
HOME
BARNES
BARNES
INSTALLATION MANUAL
Submersible Effl uent Pump
Manual Index
®
Series: EHV512
1/2 HP, 3450 RPM, 60 Hz.
83 West Drive, Bramton
Ontario, Canada L6T 2J6
Phone: (905) 457-6223
Fax: (905) 457-2650
Form No. 116350-Rev. D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BARNES EHV512 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Crane BARNES EHV512 Series

  • Page 1 Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notifi cation.
  • Page 2: Safety First

    Other brand and product names are trademarks or registered trademarks of their respective holders. ® Barnes is a registered trademark of Crane Pumps & Systems, Inc. 2003, 9/05, 5/06, 9/06 Alteration Rights Reserved...
  • Page 3: Pump Specifications

    HOME Manual Index PUMP SPECIFICATIONS: DISCHARGE ....... 2” NPT, Female, Vertical CORD ENTRY ..... 50 Ft. (15m) Cord with Plug and LIQUID TEMPERATURE ..77°F (25°C) Continuous pressure gromment for sealing and VOLUTE: ......Cast Iron, ASTM A-48, Class 30 strain relief.
  • Page 4: Section B: General Information

    B-4) Service Centers: For the location of the nearest Barnes Service Center, check your Barnes representative or Crane Pumps & Systems, Inc., C-3) Electrical Connections: Service Department in Piqua, Ohio, telephone (937) 778-8947 or Crane Pumps & Systems Canada, Inc., Bramton, Ontario, C-3.1) Power Cable:...
  • Page 5: Section D: Service And Repair

    HOME Manual Index MODEL NO VOLT/PH Hz NEMA FULL CORD CORD CORD WINDING (Nom) START LOAD SIZE TYPE O.D. RESISTANCE CODE AMPS in (mm) MAIN - START EHV512 115/1 3450 10.00 14/3 SJTOW 0.375 (9.5) 3.5 - 43 Winding Resistance ± 5%. Pump rated for operation at ±...
  • Page 6 HOME Manual Index To expose shaft seal (1) disassemble volute and impeller Make sure the stationary member is in straight. Slide a as outlined in above paragraph. Remove rotating member bullet (see parts list-seal tool kit) over motor shaft. Lightly (1b) from shaft (See Fig.
  • Page 7 HOME Manual Index F-3 MODEL NUMBER: This designation consists of numbers and letters which represent the discharge size, series, horsepower, motor phase and voltage, speed and pump design. This number is used for ordering and obtaining information. F-4 DATE CODE: The Date Code block consist of two numbers which are punched holes in the nameplates.
  • Page 8: Parts List

    HOME Manual Index FIGURE 6 PARTS LIST ITEM QTY. PART NO. DESCRIPTION 102074 Shaft Seal 099260XF Cord Set, 50Ft. PUMPS ARE SOLD AS COMPLETE UNITS ONLY, Except for the above listed parts.
  • Page 9: Troubleshooting

    HOME Manual Index TROUBLE SHOOTING CAUTION ! Always disconnect the pump from the electrical power source before handling. If the system fails to operate properly, carefully read instructions and perform maintenance recommendations. If operating problems persist, the following chart may be of assistance in identifying and correcting them: MATCH “CAUSE”...
  • Page 10: Returned Goods

    RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”. CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.
  • Page 11: Warranty Registration

    Your product is covered by the enclosed Warranty. Complete the Warranty Registration Form and return to Crane Pumps & Systems, Inc. Warranty Service Group If you have a claim under the provision of the warranty, contact your local Crane Pumps & Systems, Inc. Distributor.
  • Page 12 HOME Manual Index FOLD HERE AND TAPE, DO NOT STAPLE PLACE STAMP HERE CRANE PUMPS & SYSTEMS, INC. WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA, OHIO 45356 - U.S.A.

Table of Contents