  • Page 1 ARO 6.6H-C1-US ARO 9.9H-C1-US ARO 13.2H-C1-US ARO 16.5H-C1-US ARO 19.8H-C1-US Installation Growatt New Energy & Download Manual Operation Manual Growatt USA,Inc 9227 Reseda Blvd,#435 Northridge,CA 91324,USA. +818 800-9177 usaservice@ginverter.com www.growatt-america.com GR-UM-212-A-00...
  • Page 2 Index 1 Information on this 1.1 Validity document 1.2 Target Group 1.3 Storage of the manuals 1.4 Symbols in this document 2.1 Intended Use 2 Safety 2.2 Qualification of skilled person 2.3 Safety instruction 2.4 Certified countries 2.5 DC and AC disconnect 2.6 Operation Warnings 3 Product description 3.1 ARO-US Overview...
  • Page 3 7 Commissioning 7.2 Powering on the system 7.3 LED description 7.4 Powering off the system 7.5 Button 8 Decommissioning 8.1 Storing the ARO-US 8.2 Disposing of the ARO-US 9 Growatt Warranty 10 Technical Data 10.1 Specification 10.2 Ambient temperature 11 Contact...
  • Page 4: Information On This Document

    Earth Ground destruction of part or all of the Growatt equipment and/or other equipment connected Terre au sol to the Growatt equipment or personal injury.
  • Page 5 The ARO-US is designed and tested according to international safety requirements; however, certain safety precautions must be observed when installing and operating this ARO-US. Read and follow all instructions, cautions and warnings in this installation manual. If questions arise, please contact Growatt's technical services at +1 (818)800- 9455.
  • Page 6 Growatt can preset special grid parameters for other countries installation locations Danger of burn injuries due to hot enclosure parts! according to customer requests after evaluation by Growatt. You can make later During operation, the four sides of the enclosure lid and the heat sink may m o d i f i c a t i o n s y o u r s e l f b y c h a n g i n g s o f t w a re p a r a m e t e r s w i t h re s p e c t i v e become hot.
  • Page 7: Product Description

    Product description 3.1 ARO-US Overview Ø Make all electrical connections (e.g. conductor termination, fuses, PE connection, etc.) in accordance with prevailing regulations. When working with the ARO-US powered on, adhere to all prevailing safety regulations to minimize risk of accidents. Ø...
  • Page 8 3.2.1 Product`s label 3.2.2 Product`s label CAUTION! Risk of Electric Shock, Do Not Remove Cover. Lithium Ion Battery Lithium Ion Battery Lithium Ion Battery Lithium Ion Battery Lithium Ion Battery Lithium Ion Battery Lithium Ion Battery ARO HV Battery ARO HV Battery No User Serviceable Parts Inside ,Refer Servicing To Qualified Service Personnel.
  • Page 9: Inspection Of Delivery

    Inspection of delivery 3.2.3 Labels in the wire box 4.1 Unpacking and inspection INVERTER Port Only: The ARO-US is thoroughly tested and inspected strictly before delivery. Our ARO-US leave Link in Link out our factory in proper electrical and mechanical condition. Special packaging ensures safety and careful transportation.
  • Page 10 Instruction 5.1 Safety instruction Danger to life from electric shock due to high voltages. High voltages are present in the DC cables and later during operation in the conductive components of the ARO-US. These can cause fatal electric shocks. DANGER Danger to life due to fire or explosion .
  • Page 11 Fig 5.1 Fig 5.3 Ensure that the ARO-US is out of the children's reach. Ø Don't put any physical item on the ARO-US. Do not cover the ARO-US. Ø Ø Please make sure the ARO-US is installed at the Proper location. The ARO-US can't The location shall be away from strong electromagnetic interference.
  • Page 12 5.3.2 Fixed the ARO-US on wall In order to avoid electrical shock or other injury, inspect existing electronic or plumbing installations before drilling holes. DANGER 1.Remove the ARO 6.6-19.8H-C1-US from the box,rotate the two mounting ears which on ARO 6.6-19.8H-C1-US's back 90 degrees outward. 2.Move the ARO 6.6-19.8H-C1-US to the installation position against the wall.
  • Page 13: Electrical Connection

    Take appropriate ESD precautions when replacing and Growatt ARO-US are built according to all required safety rules. Nevertheless, improper installing the ARO-US. use may cause lethal hazards for the operator or third parties, or may result in damage to WARNING the units and other property.
  • Page 14 Convert the low-voltage direct current output from the battery pack into high- Ø voltage direct current. ARO-US can not only release the power of the battery pack but also charge the battery pack. Connection system: This ‘interface’ between ARO-US and inverter may consist of Ø...
  • Page 15 6.4 Grounding AC Grounding link-out upper battery BAT+ BAT- lower battery link-in Fig 6.4 Grounding Electrode Terminal (GET) Fig 6.7 upper battery Fig 6.6 A grounding electrode terminal may be required to local regulations. 6.5 connection lowe outer link-out lowe inner BAT+ 6.5.1 Put in the battery pack link-out lowe inner BAT-...
  • Page 16 Battery short circuits may cause personal injury. The high transient Ø current generated by a short circuit will release a surge of energy and may even cause fire. To prevent the risk of electric shock, do not connect or disconnect Ø...
  • Page 17 Commissioning High voltages in the Battery system 1.Turn on the BAT-switch on the left side of the ARO 6.6-19.8H-C1-US; Risk of death or serious injury due to electric shock 2.Open the wiring box on the right side and close the BAT-Expansion circuit breaker Only electrically skilled persons may perform work on the Battery.
  • Page 18 Middle green light flashing (0.5 Middle red light flashes (1 second on seconds on and 2 seconds off) indicate and 1 second off)indicate that the fault the standby state;Ring indicator state;Ring indicator indicate: indicate: 1) power≤25%,LED1 is on, LED2/3/4 are off; 1) power≤25%,LED1 is on, LED2/3/4 Fault state 2)power≤50%,LED1/2 are on, LED3/4...
  • Page 19 7.4 Powering off the system If the ARO 6.6-19.8H-C1-US to be forced to turn off under normal charging and discharging state, you can press and hold Power button≥3S, ≤10S (please refer to item 7.5 for power button operation), and at the same time observing the LED in the middle of the door, until the middle LED changes from green light ON to red light flashing quickly, the button can be released.
  • Page 20: Technical Data

    Charging/Dischargi 14.3A@360V14.3A@360V 14.3A@360V14.3A@360V 13.5A@360V ng Current 3500W/3500 5200W/5200 5200W/5200 5200W/5200 5200W/5200 Charging/Dischargi ng Power Growatt Warranty General Data 650*320*1160mm 130*320*1160mm Dimension(W/D/H) (25.6*12.6*45.7in) (51.2*12.6*45.7in) Please refer to the warranty card. IP Protection IP56/NEMA Type 4X Weight 105kg/232Ib 140kg/309Ib 210kg/462Ib 240kg/529Ib 270kg/596Ib Working -10-+50°C/14-122℉...
  • Page 21 Contact If you have technical problems about our products, contact the GROWATT Serviceline. We need the following information in order to provide you with the necessary assistance: Ø ARO-US type Ø Serial number of the ARO-US Ø Event number or display message of the ARO-US Ø...