Advertisement

Quick Links

© COPYRIGHT OF ASUSCOM NETWORK INC.

Chapter 1 Introduction

The proliferation of PCs and LANs with bandwidth intensive applications has generated
a powerful demand for high-speed connections. The worldwide standardization of
ISDN, combined in many countries with its growing availability and falling cost make it a
natural choice for enhancing data throughput.
ISDNL
TA-200 terminal adapters provide high-performance solutions for
Internet
INK ™
access, file transfer, remote access service, and running existing modem
applications
through the ISDN network.
ISDNL
TA-200 External Terminal Adapters
INK™
There are two ISDN interface options of ISDNL
external TA (Terminal Adapter):
INK™
ST or U interface. If you purchased the ST interface terminal adapters (TA-200ST and
TA-200ST-D), you need an ISDN NT1 device to connect to the ISDN exchange (the
NT1 box should normally be provided by your phone company). If you purchased the
U interface terminal adapters (TA-200U and TA-200U-D), they can directly connect to
the ISDN switch.
The TA-200ST and TA-200U devices support two a/b (POTS)
analog ports with connection through a supplied RJ-11 extension cable (in the UK
adapters are supplied for the standard BT connections).
The TA-200ST-D and TA-
200U-D models provide the data port connection without a/b (POTS) ports.
All of the current analog devices, including telephone set, G3 fax, answering machine,
1
modem, and PBX trunk line can be connected to the a/b port (RJ-11 jack/POTS ports)
.
The data transmission rate can be up to 64 Kbps while a normal analog communication
is taking place on on-line, or up to 128 Kbps through Multilink PPP connection using
both digital lines.
Why ISDN?
The ISDN (Integrated Services Digital Network) is the standard for carrying both data
and voice simultaneously.
ISDN BRI (Basic Rate Interface) line provides two B-
Channels for voice or data transmission.
Each B-Channel can provide data
transmission of up to 64 Kbps. The ISDN network uses the same transmission lines
as the existing analog telephone network, but uses a digital signal and higher
bandwidth between the central office (telephone company) and the customer. ISDN is
not only much faster than standard modems; it also provides an extremely reliable and
stable digital connection.
Please note that the POTS analogue ports on the TA200 device, in common with most PBX, terminal
1
adapters and fax switches, supply a reduced ring voltage. That is to say the ring voltage is lower than
that provided on a standard PSTN phone line. This does mean that in very rare circumstances some
analogue equipment may not be able to detect an incoming call.
1

Advertisement

Table of Contents
loading

Summary of Contents for Asus ISDNLINK TA-200

  • Page 1: Chapter 1 Introduction

    © COPYRIGHT OF ASUSCOM NETWORK INC. Chapter 1 Introduction The proliferation of PCs and LANs with bandwidth intensive applications has generated a powerful demand for high-speed connections. The worldwide standardization of ISDN, combined in many countries with its growing availability and falling cost make it a natural choice for enhancing data throughput.
  • Page 2 © COPYRIGHT OF ASUSCOM NETWORK INC. The ISDN network can set up a connection in about 3 seconds. This is much quicker than the PSTN network. This feature alone can result in great timesaving in the long term. Why High Speed Analog Modems Can Not Compete With ISDN Digital Connections? “The high speed modem can run at 28.8 Kbps and will move data at ISDN-type speeds when you consider data compression”.
  • Page 3: Chapter 2 Before Installation

    © COPYRIGHT OF ASUSCOM NETWORK INC. Chapter 2 Before Installation Before installation of the ISDNL external TA-200 terminal adapter, you need to INK ™ check the package contents and ensure that you have an ISDN BRI line installed. If you are using the TA-200ST(-D) device you will also require an NT1 termination device (should be provided by your telephone company).
  • Page 4: Environment Setup

    © COPYRIGHT OF ASUSCOM NETWORK INC. interface and the services they support. NT1 Connection The ISDN U-loop is terminated by NT1 device at the customer premises. connection between the NT1 and Terminal Adapter (TA) is called point “T”. The NT1 drives a 4-conductor S/T-bus, which may be expanded, to 8 conductors to provide for emergency power.
  • Page 5: Serial Port

    © COPYRIGHT OF ASUSCOM NETWORK INC. TA-200ST-D SERIAL PORT AC IN Terminators Setting AC/AC NT--1 Power Adapter AC inlet TA-200U SERIAL PORT AC IN AC/AC Power Adapter Line 1 Line 2 AC inlet Analog Line...
  • Page 6 © COPYRIGHT OF ASUSCOM NETWORK INC. Terminator setup of ISDNL “ST” interface terminal adapter INK ™ Please jump to the next section (3.) if you are the user of U interface terminal adapter, TA-200U or TA-200U-D. The ISDN S/T interface can support up to 8 ISDN terminals and through a single NT1 device for connection to the ISDN line.
  • Page 7 © COPYRIGHT OF ASUSCOM NETWORK INC. Serial and power connection Use the gray serial cable supplied to connect between the 9 pin D connector on the back of the adapter to a spare serial port connector on the rear of your computer. The supplied cable has both 9 pin and 25 pin connectors so it can be used with either size connector on your PC.
  • Page 8: Chapter 3 Installation

    © COPYRIGHT OF ASUSCOM NETWORK INC. Chapter 3 Installation After you have setup your ISDN line as described in Chapter 2 you can now, turn on your computer power ON and start the driver installation. The ISDNL TA-200 INK™ terminal adapters are communicated with by the PC as a standard modem. This means that the terminal adapter will operate on any computer or operating system, which supports standard modem operation (including MAC, UNIX and...
  • Page 9: Upgrade New Firmware

    © COPYRIGHT OF ASUSCOM NETWORK INC. Upgrade New Firmware From time to time ASUSCOM may issue updated and improved versions of the TA- 200 firmware in the form of a data file. Using this option allows the end user to upgrade the firmware using the supplied firmware file.
  • Page 10: Switch Type

    © COPYRIGHT OF ASUSCOM NETWORK INC. ISDN TA upgrade procedure starts: Erase current driver <Y/N>:_ Press “N” to finish and exit upgrade procedure and then the version number, current selected protocol and speed in B channel will be shown. If you press “...
  • Page 11 © COPYRIGHT OF ASUSCOM NETWORK INC. some of the European telephone companies. If you enter your MSN number then the telephone number of caller will be required to match the MSN value . If there is no match then the appropriate line will not answer or accept this incoming call.
  • Page 12 © COPYRIGHT OF ASUSCOM NETWORK INC. -- Packet Size : 2048 * HDLC -- Packet * V.120 Size : 256 Window Size : 7 * X.75 (Transparent) -- Packet Window Size : 7 -- Packet Size : 128 * X.75 (ISO8208) Size : 1024 Window Size : 7 ************************************************************************************ key: Exit...
  • Page 13 © COPYRIGHT OF ASUSCOM NETWORK INC. want to change the login.cmd file, you can dial into the ISP by manual login (enter ATB4 or ATB41 first, and then ATD######). Installation for Windows 95 Environment The TA-200ST is a Windows 95 PnP compatible device so Windows 95 will prompt a message and request you to install the driver when boot up.
  • Page 14 © COPYRIGHT OF ASUSCOM NETWORK INC. configuration screen. Install ASUSCOM ISDN modems. Please use the following steps to add proprietary virtual modems in Windows 95. à à à à à 1) Select Start Settings Control panel Modems Check “ do not detect my modem, I will select it from a list”.
  • Page 15 © COPYRIGHT OF ASUSCOM NETWORK INC. is used for 128K Internet Access, and the protocol in B channels is MultiLink PPP. l The ISDN TA (MultiLink PPP with BOD, 128K) or (Internet MLPPP with BOD, 128K) modem is used for 128K Internet Access, and the protocols in B channels are MultiLink PPP with Bandwidth on Demand (BOD).
  • Page 16 © COPYRIGHT OF ASUSCOM NETWORK INC. Configure the Dial-Up Networking to Access Internet Now you have correctly installed the relevant modem drivers you are ready to access the Internet through the Windows 95 Dial-Up Networking. You can make a new connection from the following steps.
  • Page 17 © COPYRIGHT OF ASUSCOM NETWORK INC. For the other fields such as Server Type, please input the values provided by your ISP. Ensure that you enter a valid ISDN connection telephone number for your ISP, remember that many ISP use a different number for normal modem and ISDN access.
  • Page 18 © COPYRIGHT OF ASUSCOM NETWORK INC. Installation for Windows NT 4.0 Environment Installing and Configuring the Drivers Run any terminal program such as Terminal, ProComm … and configure the parameters as follows Baud Rate: Up to 115200 Data Bit: Parity Check: None Stop Bit: Flow Control:...
  • Page 19 © COPYRIGHT OF ASUSCOM NETWORK INC. TA-200 installation diskette. Select the mdmasuta.inf file. 3) Select the modem type that you require from the list shown (as described below) and then click on Next, link this modem to the Com port which connects to TA- 200 terminal adapter.
  • Page 20 © COPYRIGHT OF ASUSCOM NETWORK INC. 6) If you check “Dial out only” and then click the network tab, you will get a window like below, check the protocol you want. If you are going to access Internet, check “TCP/IP” usually. 7) If you check “Receive calls”, or “Dial out and Receive calls”...
  • Page 21 © COPYRIGHT OF ASUSCOM NETWORK INC. 8) Click “Continue” and the RAS installation is finished. Please remember to restart your computer to take effect of these settings. The purpose of each modem type supported is described as follows: l The ISDN TA (Async to Sync PPP, 64K) or (Internet PPP, 64K) modem is used for 64K Internet Access, and the protocol in B channel is Async.-to- Sync.
  • Page 22 © COPYRIGHT OF ASUSCOM NETWORK INC. Configure the Dial-Up Networking to access Internet. You are now ready to configure your dial-up networking for Internet access. 64K Access for Windows NT 4.0 à à à Select Start Programs Accessories Dial-Up Networking. And then enter the name of the new Dial-Up account and click “Next >”.
  • Page 23 © COPYRIGHT OF ASUSCOM NETWORK INC. 128K/MLP Access for Windows NT 4.0 First of all check that your ISP does provide 128K connection to the internet. à à à Then select Start Programs Accessories Dial-Up Networking and then enter the name of the new Dial-Up account and click “Next >”. Enter the server type details for your ISP.
  • Page 24 © COPYRIGHT OF ASUSCOM NETWORK INC. access the Internet or network tool to access remote network. If you find problems after connecting such as the line is dropped or you cannot access the Internet, or you cannot access your remote network, please go back to check your network settings with your ISP or network administrator.
  • Page 25: Chapter 4 Provided At Command Set

    © COPYRIGHT OF ASUSCOM NETWORK INC. Chapter 4 Provided AT Command Set The ISDNL TA-200 terminal adapters support the communication interface (RS- INK ™ 232C) and allow applications to access the adapters as a standard analog modem. Extra AT commands are provided to enable ISDN features such as HDLC, X.75, V.120, or Async to Sync PPP (see command list given below).
  • Page 26 © COPYRIGHT OF ASUSCOM NETWORK INC. ATDYaNb# Y is the type of number, N is the identification of numbering plan and # is the telephone number. A = 0 unknown (default) 1 international number 2 national number 3 network specific number 4 subscriber number 6 abbreviated number b= 0 unknown (default)
  • Page 27 © COPYRIGHT OF ASUSCOM NETWORK INC. ATP=n n= 0 -> Australia 1 -> Belgium 2 -> China 3 -> Colombia 4 -> Denmark 5 -> Dutch 6 -> Euro ISDN 7 -> Finland 8 -> France 9 -> Germany 10 -> Israel 11 ->...
  • Page 28 © COPYRIGHT OF ASUSCOM NETWORK INC. ATS38 Windows size of HDLC 56K or 64K (default 7) ATS39 Packet size of HDLC 56K or 64K from 1 to 2048 (default 1024) ATS40 Windows size of V.120 (default 7) ATS41 Packet size of V.120 (default 256) ATS44 Window size of X.75 (Transparent) (default 2) ATS45...
  • Page 29 © COPYRIGHT OF ASUSCOM NETWORK INC. Escape command (default) AT&ABn Baud rate detection AT&AB0 Detect baud rate automatically, same as AT&B (default) AT&AB1 Disable auto-baud rate detection and fix to current baud rate AT&AB? Display the current baud rate AT&APn Incoming protocol detection AT&AP0 Disable incoming protocol auto-detection...
  • Page 30 © COPYRIGHT OF ASUSCOM NETWORK INC. AT&ZIr=n*m*p Set the called party number for screening incoming call (MSN). “n” is the local telephone number, “*” is the sub address symbol (option), if needed, “m” is the sub address (option). The second “*” is option. If needed, the p is the protocol indicator.
  • Page 31 © COPYRIGHT OF ASUSCOM NETWORK INC. AT$Dn n=0 disable DTR dialing (Default) n=1 enable DTR dialing (If DTR on, dial the saved telphone number 0 automatically which is saved by AT&Zr=n*m command where r=0 or 1. If DTR off, disconnect the call). This setting can be saved into profile 0 or 1 by AT&W0 or AT&W1.
  • Page 32: Appendix A Specifications

    © COPYRIGHT OF ASUSCOM NETWORK INC. Appendix A Specifications þ ISDN Interface: 1. U Interface (TA-200U & TA-200U-D) Line two-wire, full duplex Line Code 2B1Q Connector RJ-45 x 1 2. S/T Interface (TA-200ST & TA-200ST-D) Line four-wire, full duplex Line code Connector RJ-45 x 1 þ...
  • Page 33 © COPYRIGHT OF ASUSCOM NETWORK INC. þ D Channel Signaling Protocol Compatibility Euro-ISDN DSS1, 1TR6 US NI-1, NI-2, AT&T 5ESS, Nortel DMS-100 Japan INS-64 þ B Channel Protocol Compatibility Voice (TA-200ST & TA-200U) PPP, MLPPP, BOD (Bandwidth-On -Demand) HDLC, X.75 (Transparent, T.70NL, EuroFT), V.120 The specification is subjected to change without notice.
  • Page 34: Appendix B Capi20 Interface

    © COPYRIGHT OF ASUSCOM NETWORK INC. Appendix B CAPI20 Interface Installation of the CAPI20 Device Drive in Windows 95 With this interface, you can use any CAPI application such as RVS-COM or ZOC to access the TA-200 as if it were an internal INK™...
  • Page 35 System DeviceManager à ISDNLink ISDNLink TA-200 CAPI device driver. Configure the TA-200. In the properties of the CAPI driver (found in Device Manager, as above item 3), you can set the TA-200 system parameters including switch type, SPID, Standby Time, CODEC, Voice Call Type, MSN and SAD (subaddress) for POTS ports.
  • Page 36 © COPYRIGHT OF ASUSCOM NETWORK INC. (telephone number) does not match MSN and/or SAD settings ISDN Monitor (LOG) After you restart Windows95 the ISDN Monitor is executed automatically and should appear in the system tray button right of your screen. If you see the symbol appearing inside the icon as a stop sign this means the device driver can not reach ISDN terminal adapter.
  • Page 37 © COPYRIGHT OF ASUSCOM NETWORK INC. function INETEST To enable this function, please move cursor to the ISDN monitor icon and click the right button and select the Linetest function, then input your own ISDN telephone number. will do the loop back test which test from your site to the ISDN switch, then INETEST back to your site.
  • Page 38 à à Remove the ISDN TA CAPI driver from the ControlPanel System Device Manager, ISDNLink, ISDNLink TA-200 CAPI driver à Remove the ISDNLink TA-200 CAPI driver from the ControlPanel AddRemove à Software ISDNLink TA-200 CAPI driver Restart your Windows system...

Table of Contents