Download Print this page

KeLi XK3118K9-R User Manual page 9

Weighing indicator

Advertisement

2
E
PROM is changed for please input the former calibration setting and turn
on the indicator or calibrate it again.
Connection Error Notice
4.5
Display
Lack of paper, printer connection error or printer error. Please press any key
Err P
to exit. Please add paper, reconnect the printer or change with a new printer
:Serial communication data mode
Appendix 1
.
All data are the ASCII code. Each frame data is formed by 10 digits. The first digit is starting digit,
th
the 10
digit is the stopping digit and the 8 digits in the middle are the data digits. The
communication format is as follows:
I.
Continuous Sending Mode:
The sending date is the current weight of indicator (Gross weight or Net weight). Each frame is
formed by 12 groups of date. The format is as follows:
No. X Byte
1
02(XON)
2
+ or -
3
Weighing Data
Weighing Data
Weighing Data
8
Weighing Data
Decimal Digit
9
(0~4)
10
XOR Checksum
11
XOR Checksum
12
03(X0FF)
XOR Checksum=2⊕3⊕......8⊕9
II. Instruction Mode:
Indicator output the corresponding data according to the commands released by the PC.
Whenever the PC release an instruction the indicator will output one frame of data accordingly.
PC commands:
No. X
Byte
1
02(XON)
2
A~Z
A~I
Gross Weight
Command D:Read Net Weight Command E:Read Vehicle
3
No.
Command G : Clear All Record
Command I:Tare off
4
XOR Checksum
5
XOR Checksum
6
03(X0FF)
XOR Checksum =2⊕3⊕......( n-1 ) ⊕n
Indicator Output Contents
Contents and Notes
Contents and Notes
Command A:Handshake
Command C:Read Tare
Command F:Read Cargo No.
Note
Start
Symbol Bit
High Bit
Low Bit
From Right to Left
High Four Digit
Low Four Digit
Over
Start
Address Serial No.
Command B:Read
Command H: Zero
High Four Digit
Low Four Digit
Over

Advertisement