Page 1
Apparatus Operation and Instruction Manual REV C Koehler Instrument Company, Inc. 1595 Sycamore Avenue • Bohemia, New York 11716-1796 • USA Toll Free: 1-800-878-9070 (US only) • Tel: +1 631 589 3800 • Fax: +1 631 589 3815 http://www.koehlerinstrument.com • e-mail: info@koehlerinstrument.com...
Page 3
NF T 60-117 This unit is tested before it leaves the factory, to ensure total functionality and compliance to the above specifications and ASTM standards. Test and inspection records are on file for verification. Jesse Kelly Application Engineer Koehler Instrument Company...
Page 7
Responsibility for Registration and Annual Reporting: Koehler will not sell directly to end users in the EU and so has no responsibility to register within each EU state and to make annual reports. Koehler declares that this responsibility is born by the importer who is the first level of the distribution chain and is subject to producer responsibility.
Page 8
Koehler is defined as a "new WEEE producer". As such we must provide information on refurbishment, treatment, and re-use. Our instrument manual will include this compliance statement and indicate that any collection of materials will be handled by their authorized distributor. In the event that the distributor is unreachable or is no longer a distributor for Koehler Instrument, Co., other arrangements may be made including...
FTM Publication: requirements and provide you with the best FTM 791-5002 solutions. You can depend on Koehler for a full range of accurate and reliable instrumentation Instrument Specifications as well as support for your laboratory testing programs.
K27190 Ramsbottom Carbon Residue Operation and Instruction Manual return to normal operating temperatures, and Software Specifications resetting the power to the unit. PC System Intel Pentium III Processor Chemical Reagents Information. Chemicals Requirements: or similar (minimum) and reagents used in performing the test may exhibit potential hazards.
Do not return goods to Koehler Also, check that the power switch is in the off without written authorization. position before connecting the line cord at any time.
Koehler if needed. Place the required protective equipment or serious injury balance on a firm, level surface. The Koehler could occur. balance may be leveled by making minor turning...
K27190 Ramsbottom Carbon Residue Operation and Instruction Manual setting the calibration in the digital and then reinsert the plunger. Pull the temperature controller are given in spring-loaded cap over the top of the section 4.3. plunger and carefully set it down on the plunger.
This operation should be Koehler factory. Please do NOT attempt done when installing a new unit, after to re-program the digital temperature replacing or changing the bath medium type, controller as this will void the product or utilizing a different temperature set point warranty.
Over Power Protection 3. Control Bulb Maintenance. The control The Koehler Ramsbottom Carbon Residue bulb should be kept clean using a cleaning Tester is equipped with Over-power Protection solution on the exterior face.
Warranty Some returns cannot be authorized, including certain products purchased from outside We, at Koehler, would like to thank you for vendors for the convenience of the customer, your equipment purchase, which is protected by products manufactured special order, the following warranty. If within one (1) year from...