Electrical Adjustments - Sony HMC-MD777 Service Manual

Cd player/mini disc deck
Table of Contents

Advertisement

MD SECTION
1. PRECAUTIONS FOR CHECKING LASER DIODE
EMISSINON
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
2. PRECAUTIONS FOR USE OF OPTICAL
PICK-UP (KMS-260B)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before con-
necting the connector, be careful not to remove the solder. Also
take adequate measures to prevent damage by static electricity.
Handle the flexible board with care as it breaks easily.
pick-up
Optical pick-up flexible board
3. PRECAUTIONS FOR ADJUSTMENTS
1. When replacing the following parts, perform the adjustments
and checks with ¬ in the order shown in the following table.
Optical
Pick-up
IC171
1. Initial setting of
¬
adjustment value
2. Recording of IOP
information
¬
(Value written on
the pick-up)
3. Temperature
compensation
G
offset adjustment
4. Laser power
¬
adjustment
5. Traverse
¬
adjustment
6. Focus bias
¬
adjustment
7. Error rate check
¬
8. Auto gain output
¬
level adjustment
2. Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
Perform the adjustments and checks in "group S" of the test
mode.
3. Perform the adjustments to be needed in the order shown.
SECTION 5

ELECTRICAL ADJUSTMENTS

flexible board
laser tap
BD (MD) Board
IC101, IC121
IC192
D101
¬
G
¬
¬
G
G
¬
¬
G
¬
G
¬
¬
G
¬
¬
G
¬
¬
G
¬
¬
G
¬
4. Use the following tools and measuring devices.
• Extension cable (19P) (Part No. J-2501-011-B)
Relay connector (Part No. J-2501-167-A)
(BD (CD) board CN101 to MICROCOMPUTER board
CN300)
• Extension cable (17P) (with connector)
(Part No. J-2501-167-A)
(CONNECTOR board CN701 to MICROCOMPUTER
board CN301)
• Extension cable (4P) (with connector)
(Part No. J-2501-165-A)
(LOAD MOTOR board CN713 to MICROCOMPUTER
boartd CN302)
• Check Disc (MD) TDYS-1
(Part No. 4-963-646-01)
• TEST DISK (MDW-74/AU-1) (Part No. 8-892-341-41)
• Laser power meter LPM-8001 (Part No. J-2501-046-A)
or MD Laser power meter 8010S (Part No. J-2501-145-A)
• Oscilloscope (Measure after performing CAL of prove)
• Digital voltmeter
• Thermometer
• Jig for checking BD board waveform
(Part No. : J-2501-149-A)
5. When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the oscil-
loscope.
(VC and ground will become short-circuited)
6. Using the above jig enables the waveform to be checked with-
out the need to solder.
(Refer to Servicing Notes on page 6)
7. As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
Laser power meter
When performing laser power checks and adjustment (electrical
adjustment), use of the new MD laser power meter 8010S (J-2501-
145-A) instead of the conventional laser power meter is conve-
nient.
G
It sharply reduces the time and trouble to set the laser power meter
sensor onto the objective lens of the pick-up.
4. CREATING CONTINUOUSLY RECORDED DISC
G
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recorded
disc.
1. Insert a disc (blank disc) commercially available.
G
2. Turn the ≠↔± dial to display "CREC MODE" (C31).
[ENTER/YES]
3. Press the
Display "CREC (0300)" and start to recording.
¬
4. Complete recording within 5 minutes.
[MENU/NO]
5. Press the
6. Press the § (MD) button and take out the disc.
G
The above has been how to create a continuous recorded data for
G
the focus bias adjustment and error rate check.
Note :
• Be careful not to apply vibration during continuous recording.
G
G
– 32 –
button to display "CREC MID".
button to stop recording .

Advertisement

Table of Contents
loading

Table of Contents