Napoleon CONTINENTAL CEFB26H Installation And Operation Manual page 24

Table of Contents

Advertisement

Available languages

Available languages

Flame does not
troubleshooting
EN
move.
Ember bed is
not glowing or
dimming.
LED fl ashing
"OH".
Delayed fan.
24
W415-2971 / C / 11.18.22
Main PCB board issue.
Motor is stalled/malfunctioning.
Brightness not selected.
Ember LED issue.
Main PCB board issue.
Appliance has overheated
and safety thermal switch has
tripped.
The fan is delayed.
Inspect the main PCB board and replace, if necessary.
Cycle on/off. If problem persists, consult dealer.
See "operation" section.
Inspect the ember bed LEDs and replace, if necessary.
Inspect the main PCB board and replace, if necessary.
The buzzer emits a warning sound BI one time, the nixie tube
fl ashes "OH," all functions and buttons are invalid, and all
buttons are off. If the button is pressed, an alarm is issued.
Unplug power or turn off the circuit breaker. Allow appliance
to cool for 15 minutes, then plug in the appliance or turn the
breaker on. If problem persists, consults your dealer.
If the heating time is less than one minute, the fan delay is
20 seconds; if the heating time is more than one minute,
less than fi ve minutes, the fan delay is 40 seconds; if
the heating time is more than fi ve minutes, less than 10
minutes, the fan delay is 70 seconds; if the heating time is
longer than 10 minutes, less than 30 minutes, the delay is
two minutes; if the heating time is longer than 30 minutes,
the fan delay is three minutes.
27.5A