On the main screen and the settings screen, use this button to change menu Select button options and settings. Connects the Elements Connect motor handpiece and the Apex Connect only. Connector terminal It cannot be used for charging. Battery Release button Removes the battery from the motor handpiece.
Motor Settings Auto- R&S When the set torque limit is reached, the reverse motor rotates in the opposite direction of Settings the current setting until the load decreases and stops. When the torque limit value is reached, the motor rotates in the opposite direction of the current setting until the load decreases.
INDICATIONS FOR USE warranty service. • Do not spray the motor handpiece or the base with The Elements Connect motorized handpiece can be used to disinfectants. Use a cloth or a wipe moistened in enlarge and prepare root canals, remove gutta-percha points.
Elements Connect, including cables specified by the Warning Kerr Corporation. • The EMISSIONS characteristics of this equipment make it suitable for use in industrial areas and hospitals (CISPR 11 WEEE Marking class A). If it is used in a residential environment (for which...
• Insert the protrusion of the battery into the groove on the back of the motor handpiece, and then push it until it clicks. PRECAUTIONS • Do not install any contra angle other than the contra angle included in the package to the motor handpiece. •...
• To stop the motor operation, press the [Main] button. PREPARING THE DEVICE FOR USE Here, the memory number and motor operation settings can be adjusted on the main screen. Preparation and User Environment • If [CW], [CCW], [Adaptive] [RCP] are selected as the motor operation method, the files can be rotated in the The environmental information appropriate for using this device...
ADVANCED SETTINGS PRECAUTIONS • When using the rotary file, set the angle of CW bigger Linking the Elements Connect Cordless Endodontic Motor than CCW. to the Apex Connect • When using the reciprocating file, set the angle of This device can be used in conjunction with the Apex Connect.
Page 9
1. 1. Refer to “USING THE DEVICE > Basic functions” in the 6. To remove pull the lip hook connector from the probe cord. Elements Connect Endodontic Motor Instructions for use to set the memory number and the motor operation method.
7. Pull out the USB connectors at both ends of the probe cord from the motor handpiece and Apex Connect unit PRECAUTIONS 8. Refer to “Disassembling the Device” in the Elements • Do not use organic solvents such as thinner, benzene, or methanol to clean the device.
2. Thoroughly clean the surfaces of the lip hook with a tissue Outside of these hours, email us at KerrCustCare@kavokerr.com. containing isopropyl alcohol (e.g., CaviWipes). Alternatively, contact the dealer or Kerr Endodontics sales • Wipe the surface of the lip hook at least twice in representative.
Basic EMC Test level/requirement In the case other parts are used which constitutes an standard or improvement, Kerr Endodontics may, at its discretion, charge the test method customer for the additional cost of these parts. If the warranty Mains terminal...
Page 13
Phenomenon Basic EMC Test level/requirement standard or test method Radiated RF IEC 61000-4-3 3 V/m Electromagnetic Field EN 61000-4-3 80 MHz - 2.7 GHz Immunity 80% AM at 1 kHz Immunity to IEC 61000-4-3 Table 9 in Proximity Fields EN 61000-4-3 IEC 60601-1-2: 2014 from RF wireless Communications...
Page 14
Distributed By Kerr Corporation 1889 W. Mission Blvd. Pomona, CA 91766 USA 1-800-KERR-123 | kerrdental.com Manufactured By Meta Systems Co., Ltd. #1214-18, Sicox tower 12F, 484 Dunchon-daero, Jungwon-gu Seongnam-si, Gyeonggi-do 13229, Korea Distribution Facility: Kerr Australia Pty. Ltd. 12 Mars Rd., Unit 6 Lane Cove West NSW, 2066 Australia +61 2 8870 3000...