HBS CA 08 Operating Manual page 31

Stud welding gun
Table of Contents

Advertisement

Fault
Welding gun does not
weld
Welding gun does not
lift, in spite of
,
and
No
display
Work marked with *) may only be carried out by qualified electricians!
‹ Please contact our Service department if none of the measures described
remedies the situation.
‹ Please use the form „Service & Repair" in the annex to send in the stud
welding unit or stud welding gun.
©HBS Bolzenschweiss-Systeme GmbH & Co. KG
All rights reserved – Reprinting, in whole or in part, only with the approval of the manufacturer
Possible cause
Fault localisation
Ground connection
Check, whether ground
defective (no contact
cable is connected to
signal on stud welding
workpiece in a technically
unit)
correct way
Check ground cable for
electrical flow *)
Stud welding unit
Follow the instructions
defective
of the connected stud
welding unit
No lift adjusted
Check adjusted parame-
ters on welding gun
Short circuit of magne-
Meassure resistance
tic circuit of the welding
value at control cable
gu
connector (18 Ω to 22 Ω)
between Pin 1 and
Pin 2 *)
Solenoid defective
Meassure solenoid (18 Ω
to 22 Ω) *)
Magnetic circuit inter-
Meassure resistance
rupted
value at control cable
connector (18 Ω to 22 Ω)
between Pin 1 and
Pin 2 *)
12 Troubleshooting
Fault remedy
Performance
Connect ground cable
Trained personnel
In case of no flow:
Qualified specialists
Replace ground
cable *)
Repair required
Factory service or
authorised agencies
Change adjusted para-
Trained personnel
meters
Replace control cable
Qualified specialists
connector, control cable
and solenoid *)
Replace solenoid *)
Qualified specialists
Replace solenoid or
Qualified specialists
control cable *)
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

92-20-255

Table of Contents