14.HOW TO REMOVE EACH PART AND PWB FROM THE BASE CABINET ASS'Y.
1) Remove the Wi-Fi adapter, FLOAT PWB HOLDER, the LX75 FLOAT-K UNIT and the LX75 POSITION-K UNIT.
Wi-Fi adapter
FLOAT PWB HOLDER
REPLACE Wi-Fi ADAPTER
The S-B01 WF PWB UNIT contains a
screw
Wi-Fi adapter for service.
This label not use
LX75 FLOAT-K UNIT
①Replace the Wi-Fi adapter in unit with the Wi-Fi adapter for service.
※Please firm-up the Wi-Fi adapter following T/R No. EHH-627.
※Please search by publish No. EHH-627 at documents search criteria in Service Support System.
You may not be able to search by the model name of the product.
②It's necessary to make the Wi-Fi connecting setting again.
※Please finish the initial connection setting after replaced Wi-Fi adapter, the procedure
is same as when you just bought the Air purifier.
LX75 POSITION-K UNIT
2) Remove DUST SENSOR.
DUST SENSOR