Sharp KI-N50E-H Service Manual page 28

Advertisement

No.
Trouble
10
Abnormal noise is heard. Defective motor installation
11
Monitor does not display
normally.
Does not humidify.
12
13
The water of the tank do
not decrease.
14
The water supply
indicator light doesn't
flash even if water is lost.
15
The water supply
indicator light flash even
if water is put in.
16
The wind of the air outlet
smells.
Possible cause and symptom
Defective fan installation
Motor failure
Defective fan shape
Foreign object getting inside
Humidification motor ass'y failure
Defective Humidification motor ass'y installation
Humidification filter ass'y failure
Unit used in a location such as a kitchen where
there is oily smoke or soot.
Defective wiring
Dust sensor failure
Odor sensor failure
PWB ass'y failure
Lifetime of humidifying filter
Tank cap defective
PWB ass'y failure
Lifetime of humidifying filter
Tank cap defective
Float defective
PWB ass'y failure
Float defective
PWB ass'y failure
The odor which is stained in the HEPA filter
is discharged.
The odor which is stained in the Deodorizing filter
is discharged.
There is a smell even if the humidifying filter is maid
maintenance as shown in the manual.
Repair
Repair or Replace
Replace
Replace
Remove foreign object
Replace
Repair or Replace
Repair or Replace
Clean sensor and or replace part/board.
Repair or replace
Replace dust sensor
Replace odor sensor
Replace PWB ass'y
Replace humidifying filter (charge required)
Replace tank cap
Replace
Replace humidifying filter (charge required)
Replace tank cap
Replace
Replace PWB ass'y (display or float)
Replace
Replace PWB ass'y (display or float)
Replace HEPA filter (charge required)
Replace deodorizing filter (charge required)
Replace humidifying filter (charge required)
27
Remedy