OPERATION CHECK-1
1.OPERATION CHECK(1/2)
1-1. OPERATIONS OF VOLTAGE-DETECTION PROTECTORS.
See "OPERATION CHECK-3, -5" for TEST MODE operation.
NOTE: Don't connect load nor short speaker terminals.
a. Change the state to "TEST-4-21".
b. It tests by being automatic in order of TEST4-21(FL+) → 22(FR-) → 23(C+) → 24(SL-)
→ 25(SR+) → ( 26(SBL-) → 27(SBR+) ). It becomes the display of "TEST-4-35."
c. It will complete, if displayed on FL TUBE as "TEST-4-35."
d. Check operation of voltage-detection of subwoofer channnel. (HT-R391/358 only)
Change the state to "TEST-1-00".
The speaker relay is OFF immediately after D.C. +1.5v
The same as above when D.C. -1.5v
NOTE1: Limit time to apply voltage is 0.5-1.0 seconds each channel.
When protection operation does not occur at once, try several times.
NOTE2: Don't connect load nor short speaker terminals.
NOTE3: The relay shall recover in one second in "TEST-1-00". So it shall not be hold OFF.
1-2. OPERATIONS OF CURRENT-DETECTION PROTECTORS
See "OPERATION CHECK-3, -4" for TEST MODE operation.
a. Change the state to "TEST-4-35".
Even if you connect 3-ohm load for every channel of L, R, C, SL, SR, SBL,SBR and SWch, a relay should not cut off.
If 1-ohm load is connected for every channel of L, R, C, SL, SR,SBL,SBR and SWch, a relay should hold the state of ON.
1-3. CONFIRMATION OF RDS (RADIO DATA SYSTEM) OPERATION (Applied to MPP/MPB type)
a. Input 98MHz,30dBμ signal modurated with RDS data.
b. When a PS information is received, the name of the station "RDS TEST" shall be displayed within 2 seconds instead of the frequency.
1-4. CONFIRMATION OF HEAD PHONE OPERATION.
Confirm the Listening Mode is automatically switched to "STEREO" mode when headphones plug is inserted into the PHONES jack.
1-5. COMFIRMATION OF USB(Except of HT-R358)
See "OPERATION CHECK-3, -4" for TEST MODE operation.
a. Connect ipod to AVR USB port.
b. When set to TEST-3-10, confirm that the display of AVR change "connecting" to "press Push [MODE] button ...." or "iPod"
after few seconds.
The following iPod models can be used for inspection.(The above-mentioned operation is not done excluding the following items.)
iPod classic, 3G nano, 4G nano, 5G nano
1-6. CONFIRMATION OF OUTPUT SENSOR AND THERMAL SENSER.
See "OPERATION CHECK-3, -5" for TEST MODE operation.
a. Set the TEST MODE to "TEST-4-36" and "TEST-4-37".
After light "FM STEREO" on FL display, the relays RL691/692 is OFF and "FM STEREO"is off .(TEST4-37 is only for HT-R591.)
b. Push ON/Standby button while pushing down DISPLAY button to display CPU PROGRAM version.
Push TONE button while displaying CPU PROGRAM version to display value of temparature sensor.
Confirm outside temperature ±20C is displayed immediately after energizing.
Note that the error margin is caused by the rise of the temperature of the heat sink when time passes.
Voltage
Temparature
of VOLH port
of thermal sensoor
TX-SR313/ NR414/ HT-R391/358/558/591/758/ RC430/440
3v is put at J4082 J4090 to check SW.
3v is put at each place.
No singal condition (Ex. Display)
>00 034 F:x
S:H
FAN condition
x: Stop
L: Low speed
M: Mid speed
H: High speed
Amplifier power
supply voltage condition
H: High-B
L: Low-B