Siemens SITRANS F Compact Operating Instructions page 3

Coriolis flowmeters
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
SITRANS FCS200
Avoid vibrations
● Make sure that any valves or pumps upstream of the sensor do not cavitate and do not send vibration into the sensor.
Figure 4
Eliminate vibrations
Avoid cross talk
If operating more than one flowmeter in one or multiple interconnected pipelines there is a risk of cross talk.
Prevent cross talk as follows:
● Mount sensors on separate steelframes
● Keep sufficient distance between the sensors (distance depends on application)
● Decouple the pipelines.
Connecting
1. Connect transmitter and sensor using a SITRANS F C standard blue cable.
Figure 5
Electrical connection of sensor
SITRANS FCS200
A5E02914253-02, 03/2011