Safety Considerations
Lamp Replacement
It is a safety requirement that lighting loads be electrically isolated for relamping. To
do this, use the air-gap switch to the right of the adorne device as shown and move the
switch upwards. When the LED goes out, the load is safely isolated for relamping. To
restore normal operation, move the switch back to the down position.
Dimmer Derating
For multi-gang installations, use pliers to break off the specified heat sink fins.
De-rate the maximum load according to the following table.
Rated Load
Incandescent/Halogen
700W
MLV
700VA
EFL
5.5A
ELV
700W
Overload Protection
adorne Wireless Lighting dimmers and switches feature overload and short-circuit
protection. In the event of an overload condition, the device will stop working, and the
status LED will be rapidly flashing red at 2 Hz. Set the dimmer to off, disconnect loads
in excess of the dimmer's rating, and try again.
SAFETY CONSIDERATIONS
Airgap Switch
2-Gang Installation
3-Gang Installation
600W/600W
600W/500W/600W
600VA/600VA
600VA/500VA/600VA
5.5A/5.5A
5A/5A/5A
600W/600W
600W/500W/600W