Operating The System - LEGRAND adorne ADWR700MMTU User Manual

Wireless lighting control products
Table of Contents

Advertisement

EXPANDING THE SYSTEM AND INTERFACING WITH OTHER PROGRAMS
Common Device Applications
Security Systems
Connect adorne Scene Interfaces and security systems using a two-wire connection between a maintained
or momentary output relay at the alarm panel and the desired input on the scene interface. Common
applications include switching on or flashing house lighting when an alarm event occurs or recalling a
scene when the homeowner deactivates the alarm system upon arrival.
y
u r i t
S e c
e l
P a n
Occupancy or Vacancy Sensor
An occupancy sensor application could use either Mode A or Mode B. Most applications would use Mode B.
In this configuration, a scene executes when the sensor initially detects motion; a second scene executes
when the sensor determines that the space is unoccupied. Mode A allows auto-on, manual-off, and
manual-on/auto-off functions. A manual-on/auto-off application requires the input to be wired to a NC
contact and the scene stored to turn the appropriate lighting off.
Motion
Sensor
16
2/20AWG
Power
24VDC Out.
(150ma max.)
Ground
Ground
COM
Input 1
NO
Input 2
Input 3
Room or House
Scene Interface
Using adorne Wireless Lighting Dimmers, Switches, and
Plug-In Modules
Dimmers
Setting
Default
On/Off
Tap once
On/Off
Tap twice
On/Off
Press and hold
+ or upper-right
Tap once
+ or upper-right
Tap once
+ or upper-right
Tap twice
+ or upper-right
Tap twice
+ or upper-right
Press and hold
- or lower-right
Tap once
- or lower-right
Tap twice
- or lower-right
Press and hold
Plug-in Lamp Modules
Setting
Default
Tap once
Tap twice
Press and hold
Tap once
Press and hold
Switches
Setting
Default
On/Off
Tap once
On/Off
Tap once
Plug-in Appliance Modules
Setting
Default
Tap once
Press and hold
Tap once
Press and hold

OPERATING THE SYSTEM

Button Operation
Fade the circuit to its last-used level
Full bright
Fade the circuit to off
From Off, fade the circuit to its last-used level
From On, increase level 2% per tap
From Off, full bright
From On, increase level 4%
Continually increase the light level
Decrease level by 2% per tap
Decrease level by 4%
Continually decrease the light level
Button Operation
Fade the circuit to its last-used level
Full bright
Continually increase the light level
Fades the circuit to off
Continually decrease the light level
Button Operation
From Off, turn circuit on
From On, turn circuit off
Button Operation
Turn circuit on
Turn circuit on
Turn circuit off
Turn circuit off
17