Wiegand Keypad / Card Reader
These instructions apply to the following DoorKing Products: 1815-247, 1815-248, 1815-249, 1815-250 with circuit
board P/N 1515-009.
When used to control entry through an automated vehicular gate system, the keypad / card reader must be
mounted a minimum of 10-feet away from the gate and gate operator, or mounted in such a way that the
person using the keypad cannot come into contact with the gate or gate operator.
Both the keypad and card reader output their data in a 26-bit wiegand format and must be connected to an access
controller such as the DKS models 1833, 1835, 1837 or 1838. Each device operates independently of each other.
1 Common (Black)
2 Power (Red)
3 Earth Ground
4 Wiegand Common
5 Not Used
6 Data 0 (Green)
7 Data 1 (White)
8 Not Used
1815-864-B-3-16
1 2 3 4 5 6 7 8
Gray
12-24 Volt AC or DC
Orange
12-24 Volt AC or DC
Green
Data 0
White
Data 1
To Access Controller
Black
Common
Red
Power
Keypad OR Card opens door/gate
Connect the keypad terminals to the card reader terminals (Red,
Black, Green, White) and then connect to access controller.
Keypad AND Card opens door/gate
Each device must have separate weigand wire runs to the
controller with each device operating a different controller relay.
Relay contacts are wired in series to device to be controlled.
Suggest setting relay strike times to 5 sec.
Keypad / Card opens different doors/gates
Each device must have separate weigand wire runs to the
controller with each device operating a different controller relay.
Relay contacts are wired to individual devices to be controlled.
White
Green
Red
Black
Gray
Orange
Power for LED Lights

Advertisement

loading

Summary of Contents for DoorKing 1815-247

  • Page 1 Wiegand Keypad / Card Reader These instructions apply to the following DoorKing Products: 1815-247, 1815-248, 1815-249, 1815-250 with circuit board P/N 1515-009. When used to control entry through an automated vehicular gate system, the keypad / card reader must be mounted a minimum of 10-feet away from the gate and gate operator, or mounted in such a way that the person using the keypad cannot come into contact with the gate or gate operator.
  • Page 2 PROGRAMMING MASTER CODE Press the master code button on the circuit board once. Enter a four-digit code _ _ _ _ then press * (beep). FACILITY CODE Press * 4 and the four-digit master code _ _ _ _ (beep). Enter a three-digit facility code _ _ _ (000-255) then press * (beep).

This manual is also suitable for:

1815-2481815-2491815-250