Recognising And Repairing Of Mistakes; Guarantee Regulations; Notes On Product Liability; Notes On Disposal - Profi-pumpe OASIS 501R-1 Operating Instructions Manual

Solar pond pump
Hide thumbs Also See for OASIS 501R-1:
Table of Contents

Advertisement

Available languages

Available languages

6 English

12. RECOGNISING AND REPAIRING OF MISTAKES

Problem
Pump will not turn on
Pump runs but no
water is encouraged
No proper water
fountain

13. GUARANTEE REGULATIONS

For all manufacturer defects and material defects we grant the legal guarantee time (new and unused product).
In such cases we take over the exchange or the repair of the pump. Forwarding expenses are not carried by us.
The guarantee is not valid with:
l Material wear (sealing rings, impeller wheels, impeller chambers)
l Unjustified interventions or changes in the pump
l Damages by selffault
l Improper servicing and improper use
l DRY RUN (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!

14. NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no
changes were made to the equipment. We are only liable for repairs, if original spare parts and accessories were
used and repairs are carried out by our authorized service.

15. NOTES ON DISPOSAL

Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to
be disposed in your household garbage. We are registered at the German registration department EAR
under the WEEE-No. DE79535656. This symbol means, that you're not allowed to treat this product as a
regular household waste item – it has to be disposed at a recycling collection point of electrical devices.
This is the best way to save and protect our earth.
 
THANK YOU FOR YOUR SUPPORT!
In connection with the sale of batteries or with the delivery of equipment containing rechargeable battery
packs, the seller is obliged to draw your attention to the following:
You are obliged to return used batteries as an end-user. You can return batteries after use to the seller
or to the designated collection facilities, which are free of charge (eg: municipal collection points or in
stores). You can return the batteries for disposal at no charge to the seller.

16. EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf,
namely Solar-Teichpumpe „OASIS" as placed on the market, complies with the relevant provisions listed below, the
relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as
no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with
the manufacturer.
The sole authorised person to keep the technical documents: Amur S.à r.l. - 36, Rue de la Gare - L-5540 Remich
EC Electromagnetic compatibility directive (2014/30/EU)
The following harmonized standards: EN 55014-1:2017; EN 55014-2:2015; ROHS: 2011/65/EU; BS EN 55014-
1:2017 / DIN BS EN 55014-1; BS EN 55014-2:2015 / DIN BS EN 55014-2
Signed for and on behalf of Amur S.à r.l. :
Possible cause
No sunlight
Low battery power
Connector from the pump is not connected
correctly
Defective pump / solar panel broken
Pump impeller and filter housing polluted
The flow regulator on the pump is closed Open the flow regulator on the pump.
Coarsining or fountain nozzles dirty
Pump has drawn in air
(Avoid Caution! Dry running)
Fountains nozzles and tubes are dirty
Remich, 08.12.2022
i.V. Dipl. Phys. Peter Neumüller
Technical Manager
Solution
The orientation of the solar panels up to the sun
See point 6.1. (Battery information)
See point 5.4
Replace pump or solar panel. For fault isolation:
solar panel Check if the specified voltage is pro-
vided. Operate the pump to an external battery.
Disassemble and clean in accordance with
point 8, the pump and the housing (by means
of water and a soft brush)
Disassemble and clean the tube and the
fountain nozzle
Stop the pump briefly and then back on. (Re-
starting)
Clean the fountain nozzles or tubes

Advertisement

Chapters

Table of Contents
loading

Table of Contents