2. Set preferred position (outside the limits)
→
→
P2
P2
DOWN
Assure that the upper and lower limits are set. Press P2 (1 beep and 1 jog), press DOWN (1 beep and 1 jog), press
DOWN again (3 beeps and 1 jog), then press UP or DOWN to run the motor to the desired preferred position
OUTSIDE the limits, press P2 (1 beep and 1 jog), press STOP (1 beep and 1 jog), press STOP again (3 beeps and 3
jogs), the preferred position outside the travel limits is set.
NOTE: if a preferred position within the limits is already set, this must be deleted first to set a preferred position
outside the limits.
3. Run to preferred position
STOP
4. Remove preferred position
→
→
P2
P2
STOP
Adjusting Limits
1. Adjusting the upper limit position (
→
→
The upper
limit position
UP
Run the motor to the upper limit position. Press and hold the UP and DOWN buttons simultaneously for
5 seconds (3 beeps and 1 jog), then press UP or DOWN to run the motor to the new upper limit position,
then press and hold STOP for 5 seconds (3 beeps and 1 jog), the new upper limit has been set.
2. Adjusting the lower limit position
→
The lower
→
limit position
DOWN
Run the motor to the lower limit position. Press and hold the UP and DOWN buttons simultaneously for 5
seconds (3 beeps and 1 jog), then press UP or DOWN to run the motor to the new lower limit position,
then press and hold STOP for 5 seconds (3 beeps and 1 jog), the new lower limit has been set.
Pairing an Additional Remote
→
→
P2
P2
P2(a)
P2(a)
* (a) is existing remote, (b) is new remote
Deleting One Saved Remote
→
or
DOWN
UP
DOWN
Press STOP for 2 seconds, the motor will automatically run
to the preferred position.
Press P2 (1 beep and 1 jog), press STOP (1 beep and 1 jog),
press STOP again (long beep and 1 jog), the preferred
STOP
position is deleted.
This cannot be done if the limits are not already set!
+
→
UP
DOWN
+
→
UP
DOWN
One the existing programmed remote, press P2
jog), press P2 again (1 beep and 1 jog), now press P2 on the
P2
new remote (3 beeps and 1 jog). The new remote has now
been paired. The same process applies for all newly added
P2(b)
remotes, wireless switches, etc., up to a maximum of 20.
→
→
P2
P2
STOP
→
or
UP
DOWN
The new lower
→
or
limit position
UP
DOWN
14
→
STOP
)
→
The new upper
limit position
STOP
→
STOP
(1 beep and 1