Start-Up And Settings - Schartec Tube FE Installation And Operating Instructions Manual

Roller shutter motor with electronic limit setting
Table of Contents

Advertisement

Available languages

Available languages

Motor End Cap
Bracket
clip
Step 3: Mount the crown and motor end cap on
the motor. Ensure that the end cap fits firmly and
that the crown rotates freely.
Wiring
Pre-setup Notes
1.
When performing any settings changes, the interval duration between button presses is 6 seconds. If no action is taken before 6 seconds during
setup/programming of any functions (besides limit setting), then the setup/programming will be cancelled.
2.
When setting the limit positions:
a. The upper and lower limit position settings cannot be set at the same point.
b. After setting the limit positions, these positions are saved even during a power outage and/or if removing power to the motor. The same ap-
plies for a remote control: if power is removed from the motor, the learned in remote(s) will be retained.
c. Upon performing a "limit deletion" all saved opening, closing, or preferred limits will be deleted.
d. When setting the opening and closing positions, if no action is taken for 2 minutes, the motor will automatically quit the limit setting program,
no limits will be saved, and you'll need to start the limit setting program again.
3.
If the opening and closing limits are already set and a remote control should become damaged or lost, simply code in a new remote control and the
limits will not need to be reset.
4.
The motor has a maximum storage capacity of 20 channels (remotes, buttons, etc.). How to code in additional remotes, buttons, etc. will be ex-
plained below. Please be aware, however, that if more than 20 remotes, buttons, etc. are taught in, the first taught in remote will be removed.
Buttons Instructions
P1 Button
P1
Functions of the P1 Button
1.
Pairing a remote control: Press the P1 button once, the motor beeps 3 times and is ready for remote pairing (explained below).
2.
Motor direction change: Press and hold the P1 button for 5 seconds, the motor beeps 3 times and jogs once. Release the button, the motor direc-
tion of travel is now changed (this can also be changed via the remote control, is explained below).
3.
Reset motor: Press and hold the P1 button for 10 seconds, the motor will beep 3 times and jog once at 5 seconds, but continue to hold the button.
At the 10 second mark, the motor will beep again 3 times and jog once. All motor settings and limits have now been reset.
Motor crown
230V/50Hz
1
Neutral line = blue / white
2
Live line = brown / black
3
Grounding line = green / yellow

Start-up and settings

Motor bracket
Step 4: Align the notches on the crown and the motor
end cap with the shutter tube, slide and fit the motor
into the tube. Mount the brackets the desired side.
Up
Stop
Down
12
Motor
P2
P2
P2
P2
Lithium Cell