Seal & Spacer Replacement - Pentair Fleck 2510 Service Manual

Hide thumbs Also See for Fleck 2510:
Table of Contents

Advertisement

Figure 5
Figure 6
Figure 7
Seal & Spacer Replacement
1.
Turn off water supply to valve. Next, cycle
valve to backwash position, then to service.
Now remove electrical plug from outlet.
2.
Remove control box cover.
3.
Disconnect the brine line from the injector
housing to the brine valve (if your unit has
timed brine tank fi ll).
4.
Remove the two capscrews that hold the
back plate to the valve.
5.
Grasp the back plate on both sides and
slowly pull end plug and piston assembly
out of the valve body (see Figure 5) and lay
aside.
6.
Remove the seal fi rst using the wire hook
with the fi nger loop (see Figure 6).
7.
The spacer tool (use only for removing
the spacers) has three retractable pins,
retained by a rubber ring, at one end; they
are retracted or pushed out by pulling or
pushing the center button the opposite end.
8.
Insert the pin end of the spacer tool into the
valve body with the pins retracted (button
pulled back). Push the tool tight against the
spacer and push the button in (see
Figure 7). When the button is pushed in,
the pins are pushed out to engage the 1/4
dia. holes in the spacer. Remove the tool
from the valve body. The spacer will be on
the end. Pull the center button back, the
pins will be retracted and the spacer can be
removed from the spacer tool.