I Auxillary Circuit Breaker; Electrical Work - Samsung AS07A5(A6)MA Owner's Instructions Manual

Ductless mini - split
Hide thumbs Also See for AS07A5(A6)MA:
Table of Contents

Advertisement

I
NSTALLING THE
Outdoor unit
❊ The designs and shape are subject to
change according to the model.
38
E-
Get user manuals:
See SafeManuals.com
O
U
UTDOOR
NIT
Auxiliary Circuit Breaker
N
Distribution
board
N It is necessary that the conduit kit for power supply to the outdoor
Auxiliary
power s/w

Electrical Work

➢ When using the special NFB, use the NFB to bear the capacity of the
➢ Otherwise, the shot circuit in the NFB may occur.
Auxiliary circuit breaker should be installed near outdoor unit so
that each access is possible. Main/outdoor power supply cable are
connected to upper/lower terminal of auxiliary circuit breaker.
unit be installed between auxiliary power S/W and the outdoor
unit. (the conduit kit is optional)
1
The supply voltage must be the same as the rated voltage of the
air conditioner.
2
Prepare the power souce for exclusive use with the air conditioner.
3
Use 15 amperes time delay fuse or circuit breaker.
MODEL
AS07✴✴MA
Power supply
115V~/60Hz
Single phase
Power cable
Assembly cable
Operating current(C)
6.4
Starting Current
32A
Power consumption (C)
680W
MODEL
AS18✴✴RC
Power supply
208-230V~/60Hz
Single phase
Power cable
Assembly cable
3G AWG 14 + 2G AWG 18
Operating current(C)
Starting Current
Power consumption (C)
air conditioner.
AS09✴✴MA AS12✴✴MC
115V~/60Hz
208-230V~/60Hz
Single phase
Single phase
3G AWG 14
2G AWG 14 + 2G AWG 18
8.5
6.1
47A
31A
900W
1320W
AS24✴✴RC
208-230V~/60Hz
Single phase
3G AWG 12
4G AWG 14 + 2G AWG 18
8.6A
10.5A
35A
10.5A
1900W
2350W