  • Page 1 INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D’INSTALLATION Indoor Unit Outdoor Unit AS07A5(6)MA US07A5(6)MA AS09A5(6)MAF US09A5(6)MAF AS12AA(B)MCF US12AA(B)MCF Split Type Air Conditioner (Cool) Acondicionador de aire del tipo partido (Refrigeración) Climatiseur type Split (Refroidissement) E S F DB98-15774A(1)
  • Page 2 REPARING THE NSTALLATION Safety Precautions The following safety precautions must be taken when using your air conditioner. Risk of electric shock. • Can cause injury or death. • Disconnect all remote electric WARNING power supplies before servicing, installing or cleaning. • This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.
  • Page 3: Table Of Contents

    REPARING THE NSTALLATION Contents ◆ P REPARING THE NSTALLATION ■ Deciding on Where to Install the Air Conditioner ..4 ■ Air Conditioner and Accessories ....6 ◆...
  • Page 4: Reparing The Installation

    REPARING THE NSTALLATION Deciding on Where to Install the Air Conditioner When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account. General Do NOT install the air conditioner in a location where it will come into contact with the following elements: ◆...
  • Page 5 REPARING THE NSTALLATION Respect the clearances and maximum lengths indicated in the diagram below when installing the unit. 1inch(30mm) or more 5inch 5inch (125mm) (125mm) or more or more Wrap the refrigerant pipes and the drain hose up in the absorbent pad and the vinyl tape;...
  • Page 6: Air Conditioner And Accessories

    REPARING THE NSTALLATION Air Conditioner and Accessories The following accessories are supplied with the air conditioner. ➢ The quantities are indicated in parentheses. Accessories in the Indoor Unit Case Installation Plate (1) Remote Control (1) Remote control Batteries for Remote Control (2) holder(1) Terminal Block Cover Screws (2)
  • Page 7: Installing The Indoor Unit

    NSTALLING THE NDOOR Fixing the Installation Plate Before fixing the installation plate to a wall or window frame, you must determine the position of the inch(65mm) hole through which the cable, piping and hose pass to connect the indoor unit up to the outdoor unit. When facing the air conditioner in position on the wall, the piping and cable can be connected from the: ◆...
  • Page 8: Purging The Unit

    NSTALLING THE NDOOR Purging the Unit On delivery, the indoor unit is loaded with an inert gas. All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as follows. Unscrew the caps at the end of each pipe. Result: All inert gas escapes from the indoor unit.
  • Page 9 NSTALLING THE NDOOR Connecting the Assembly Cable (cont.) Detach the control box from the indoor unit. Install the conduit kit. (The conduit kit is optional) Control Box Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals as shown in the figure.
  • Page 10: Installing And Connecting The Indoor Unit Drain Hose

    NSTALLING THE NDOOR Installing and Connecting the Indoor Unit Drain Hose Care must be taken when installing the drain hose for the indoor unit to ensure that any condensation water is correctly drained outside. When passing the drain hose through the inch(65mm) hole drilled in the wall, check that none of the following situations occur.
  • Page 11: Installing And Connecting The Indoor Unit Assembly Piping

    NSTALLING THE NDOOR Installing and Connecting the Indoor Unit Assembly Piping There are two refrigerant pipes of different diameters: ◆ A smaller one for the liquid refrigerant ◆ A larger one for the gas refrigerant A short length of piping is already fitted to the air conditioner. You must extend this piping using assembly piping (optionally supplied).
  • Page 12: Cutting/Extending The Piping

    NSTALLING THE NDOOR Cutting/Extending the Piping 16.5ft(5m) of piping is supplied with the air conditioner(Optional). This length can if necessary be: ◆ Extended to a maximum of ‘L’ ft/m ◆ Shortened as required ☛ If more than 16.5ft(5m) of piping is required: ◆...
  • Page 13: Installing The Outdoor Unit

    NSTALLING THE UTDOOR Connecting the Cables to the Outdoor Unit One electric cable must be connected to the outdoor unit: ◆ The assembly cable connecting the indoor unit to the outdoor unit ✴✴07/09✴✴ Remove the terminal board cover on the side of the outdoor unit. Connect the assembly cable to terminals as shown in the figure.
  • Page 14: Auxillary Circuit Breaker

    NSTALLING THE UTDOOR Auxiliary Circuit Breaker ◆ Auxiliary circuit breaker should be installed near outdoor unit so that each access is possible. Main/outdoor power supply cable are connected to Distribution upper/lower terminal of auxiliary circuit breaker. Outdoor unit board ◆ It is necessary that the conduit kit for power supply to the outdoor Auxiliary power unit be installed between auxiliary power switch and the outdoor unit.
  • Page 15: Checking Correct Ground

    NSTALLING THE UTDOOR Checking Correct Ground If the power distribution circuit does not have the ground or the ground does not comply with specifications, the ground electrode must be installed. The corresponding accessories are not supplied with the air conditioner. Select the ground electrode that complies with the specifications given in the illustration opposite.
  • Page 16: Fixing The Unit In Position

    NSTALLING THE UTDOOR Fixing the Unit in Position The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour. If it is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support (wall or ground).
  • Page 17: Completing The Installation

    OMPLETING THE NSTALLATION Connecting Up and Purging the Circuit The outdoor unit is loaded with sufficient R22 refrigerant for 16.5ft (5m) of piping. The air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect the compressor, reduce to cooling capacity and could lead to a malfunction.
  • Page 18: Performing Leak Tests

    OMPLETING THE NSTALLATION Performing Leak Tests Before completing the installation (insulation of the cables, hose and piping and fixing of the indoor unit to the installation plate), you must check that there are no gas leaks. To check for gas leaks on the... Then, using a leak detector, check the...
  • Page 19: Placing The Indoor Unit In Position

    OMPLETING THE NSTALLATION Placing the Indoor Unit in Position Once you have checked that there are no leaks in the system, you can insulate the piping, hose and cables and place the indoor unit on the installation plate. To avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pipe in the lower part of the indoor unit.
  • Page 20: Checking And Testing Operations

    OMPLETING THE NSTALLATION Checking and Testing Operations To complete the installation, perform the following checks and tests to ensure that the air conditioner is operating correctly. Review all the following elements in the installation: ◆ Installation site strength ◆ Piping connection tightness to detect any gas leakages ◆...
  • Page 21: Explaining Operations To The Owner

    OMPLETING THE NSTALLATION Explaining Operations to the Owner Before leaving the premises on which you have installed the air conditioner, you should explain the following operations to the owner, making reference to the appropriate pages in the owner’s instruction booklet. How to start and stop the air conditioner.
  • Page 22 THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: ELECTRONICS...