INSTALLATION INSTRUCTIONS
If a pressurized storage tank is being used, the system is
equipped with a product water pressure switch, which will
shut the system off when the pressure in the tank reaches 45
PSI. The system will turn on again when the pressure in the
tank decreases to 25 PSI.
If an atmospheric storage tank is being used, a tank level float
control switch and repressurization system (optional features)
will be required to shut the system off and to pump the
product water to your application.
Remove the plug from the product water outlet (marked
PRODUCT) located in the two-way divider at the bottom of
the product water pressure switch. Connect a 3/8" OD product
water line to the marked outlet, but do not connect it to the
storage tank or other dispensing system at this time. There will
be further instructions in the System Start-Up Section
regarding additional steps required, prior to connecting the
storage tank.
DRAIN / REJECT WATER CONNECTION
A wastewater drain must be near the installation site. This will
be your connection for the reject water (drain) which is
carrying a high level of concentrated dissolved salts, minerals,
and suspended particles that were rejected by the membrane
element.
Remove the plug from the drain water outlet (marked
DRAIN) at the bottom of the reject water assembly, located
near the center of the unit. Using 3/8" OD tubing connect this
outlet port to your wastewater drain.
NOTE: We recommend installing an air gap connection
designed to prevent wastewater back flow.

ELECTRICAL CONNECTIONS

A grounded electrical supply of the proper voltage for your
system should be near the installation site. The system will be
damaged if connected to a power source other than the
voltage, phase and hertz specified on the serial number label.
See the wiring diagram at the end of this manual for the
correct power connections.
Every LP3 Series 60Hz, 120V, 1Ph model comes equipped
with an In-Line On/Off Toggle Switch – conveniently located
next to the system pressure switches. Please reference the
wiring diagram at the end of this manual for more information.
CAUTION – While the On/Off Toggle Switch
may be in the OFF position, the power cord
should still be unplugged for any servicing or
maintenance to the Reo-Pure™ RO System.
Optional 50Hz, 220V, 1Ph Power – If your system was
ordered with the optional 50Hz, 220V, 1Ph feature, you will
need to provide your own electrical plug. Attach the
appropriate plug to the end of the 14-3 cord that is connected
to the Inlet Feed Water Low Pressure Switch.
Please refer to the section titled "Filter Cartridge Installation
and Replacement" in this manual.
To ensure the highest level of reliability and system longevity,
red locking clips have been installed on all John Guest tubing
connections. This will make the connections more secure and
protect the system from accidental disconnects. Two extra
locking clips have been included with this manual. These
should be attached at the product and drain ports of the
system, after you have made your connections.
IMPORTANT   –   Installation must comply with state and
local plumbing, electrical, and sanitation codes.  
 
IMPORTANT   – Prior to the start-up of system, visually
inspect the inlet, drain, and product water connections
completely. Also check to be sure the system is
connected to a properly grounded electrical power supply
with the appropriate voltage, phase, and hertz.
 
(continued)
CAUTION – A water softener should not be
allowed to regenerate while the Reo-Pure
System is operating, unless safeguards are
used to be sure the system is shutdown or
operating on an alternate source of softened
water.
CAUTION Connecting the system to a
power source that does not match the system
power rating exactly can damage the system
and void the warranty.

INSTALL FILTER CARTRIDGES

JOHN GUEST LOCKING CLIPS

LP3-­‐‑ 3 50   O wner's   M anual   |     6  
 