REO-PURE LP3-350 SYSTEM TROUBLESHOOTING
PROBLEM  
BAD  
TASTING  
WATER  
CLOUDY  
Dissolved  air  in  feed  water  concentrated  in  
WATER  
HIGH  TDS  IN  
PRODUCT  
WATER  
Product  tube  o-­rings  damaged  or  out  of  place  
 
 
POSSIBLE  CAUSE  
Increase  in  feed  water  TDS  
Filter  cartridges  exhausted  
Tank  and  system  contaminated  
Tank  contaminated  
Tank  diaphragm  ruptured  
Membrane  not  flushed  completely  
product  water  
Membrane  element  expended  
Insufficient  brine  flow  rate  
Increase  in  feed  water  TDS  
SOLUTION  
Check  feed  water  TDS  
Replace  filter  cartridges  
Replace  filter  cartridges  and  membrane,  sanitize  
system  and  tank  
Re-­sanitize  tank  
Replace  tank  
Flush  one  or  two  tanks  of  product  water  to  drain  
Usually  clears  up  as  condition  of  feed  water  changes.    
Letting  water  stand  will  allow  dissolved  air  to  dissipate  
Check,  replace  if  necessary  
Check,  reject  flow  must  be  at  least  equal  to  product  
Check  inlet  TDS,  see  Operating  Specifications  for  
rejection  rate.  
Remove  membrane  element  from  housing.    Re-­install  
or  replace  o-­rings  on  membrane  element  product  tube  
LP3-­‐‑ 3 50   O wner's   M anual   |     2 0  
(continued)
flow  