Summary of Contents for lakeair LAFC-RC2

  • Page 1 Operating and Service Instructions Model LAFC-RC2 Electrostatic & HEPA 120 V Self Contained – Flush Ceiling Mounted Electronic Air Cleaner – Model LAFC-RC2-HEPA RK Ventures Inc. Racine,wi 1509 Rapds Drive www.lakeair.com sales@lakeair.com 800-558-9436...
  • Page 2: Table Of Contents

    Component Ch ecks Check Fan Motor and Power Source Check the Electronic Cell Check for Short Circuits Check Transformer and Voltage Doubler Troubleshooting Flowchart Electrical Connections Electrical Schematic LakeAir Electronic Air Cleaners 7 Year Limited Warranty User’s Responsibility Model LAFC Parts Schematic...
  • Page 3: Introduction

    That air is filled with particles of Recirculated Air for Comfort and Savings smoke, dust, pollen, microor-ganisms, and other With the use of your LakeAir brand Air Cleaner, pollutants. With your new LakeAir HEPA air you will find that bothersome smoke and other...
  • Page 4 COMPONENTS OF THE LAFC-RC2-HEPA & LAFC-RC2-HUV Filtration Media Hood Assembly The LAFC-RC2 uses a commercial True HEPA filter The LAFC is fitted with a corrosion resistant to remove 99.97% of airborne particles. The Pre-Filter galvanized steel hood which requires only 11.25” of removes large items form the air stream and prolongs space above the drop ceiling for installation.
  • Page 5: How Your Lafc Model Works

    In business establishments or public buildings, millions of airborne particles are continually being circulated in the air you breathe. Your LakeAir Model LAFC Self Contained Flush Mounted Electronic Air Cleaner removes the smoke, dust, dirt, pollen, and other pollutants from the air with an electrostatic process which works this way: 1.
  • Page 6: Installation Instructions

    INSTALLATION INSTRUCTIONS IT IS IMPORTANT TO READ THE FOLLOWING INSTRUCTIONS CAREFULLY. DAMAGE TO THE PRODUCT OR TO INSTALLER AND PROPERTY COULD RE-SULT IF INSTRUCTIONS ARE NOT FOLLOWED. Important Safety Precautions Do not connect the power source until after the unit is mounted. Shock and/or damage could result.
  • Page 7 The wire coming from the unit (unless ordered with on-board speed control) has 6 conductors. You can purchase more wire from LakeAir if needed. This wire should be of sufficient gauge for run lengths under 40 feet.
  • Page 8: General Information

    GENERAL INFORMATION: Application The Model LAFC-RC2 should be mounted in the room or area where the air is to be cleaned. Removal of such pollutants as tobacco smoke and viruses from the air in areas like conference rooms, lounges, schools, offices and the like is the goal of the unit.
  • Page 9: Replacing The Hepa Media Pad

    Service Should your LakeAir LAFC malfunction, there are several simple checks which you can use to check the performance before a service person need be called. Check to see if the fuse on the unit is tripped which would indicate electrical interruption to the unit.
  • Page 10: Troubleshooting Guide And Chart

    Carbon filters should be replaced when odors re-appear Electrostatic filter cell should be inspected to see when dirty NEVER OPPERTAE UVGI WITHOUT CARBON FILTERS LakeAir MODEL LAFC TROUBLESHOOTING GUIDE AND CHART WARNING!!! The following instructions are intended for qualified service personnel only.
  • Page 11: Powering Up The Lafc

    LakeAir MODEL LAFC TROUBLESHOOTING GUIDE AND CHART 1. Powering up the LAFC Make sure the prefilter screen and electronic filter are clean, dry, and properly + installed in the air cleaner. Turn on the LAFC and check to make sure all systems are in proper working order. In each case, the system light should be on and the fan should run.
  • Page 12 Specifications Capacity............300-1500 cfm Standard HEPA Filter....... 4.5 inch mini pleat UVGI HEPA Filter........2.4 inch mini pleat HEPA Efficiency........99.97% to 0.3 micron Electrostatic Precipitator ........ 4.5 inch / 5kv Cell Collection Area........5000 sq. inches Electrostatic Efficiency......97% to 0.1 micron MERV 15 Media ....
  • Page 13: Electrical Schematic

    HEPA Filter #499081 Other parts in the LAFC assembly can be obtained by calling or writing to RK Ventures, Inc. Customer Service Department. Phone 800-558-9436 RK Ventures Inc Fax 262-632-3144 1509 Rapids Drive Suite 23 Email sales@lakeair.com Racine WI 53404 www.lakeair.com...
  • Page 14: User's Responsibility

    The blowers of the LakeAir MAX Guard is warranted for (1) year from the date of purchase to the original purchaser. A extended blower warranty is available for purchase and extends the warranty to 7 years.
  • Page 15 If you have questions or need support it can be found in many ways. Email: Email support can be obtained by sending an email to sales@lakeair.com. We try to answer all email support matters within 12 hours. If emails are sent during regular business hours 8:00 AM - 6:00 PM CST replies should be much sooner.