lakeair LA2-RC2-HUV Operating And Service Instructions

Warning this product utilizes germicidal uv which maybe dangerous

Advertisement

Quick Links

Warning this product utilizes
Germicidal UV which maybe
Dangerous
OPERATING AND SERVICE
INSTRUCTIONS
LA2-RC2-HUV
RK Ventures Inc
www.lakeair.com

Advertisement

Table of Contents
loading

Summary of Contents for lakeair LA2-RC2-HUV

  • Page 1 Warning this product utilizes Germicidal UV which maybe Dangerous OPERATING AND SERVICE INSTRUCTIONS LA2-RC2-HUV RK Ventures Inc www.lakeair.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction Page 3 Specifications Page 3 Installation Page 4 Units needed for your space Page 4 Location of units in a room Page 5 Mounting the LA2-RC1-HUV Page 5-6 Operating Instructions Page 6 Filter and bulb replacement Page 7 -10 Repair and maintenance Page 11...
  • Page 3: Introduction

    A. How the LakeAir LA2-RC2-HUV works In business establishments, millions of airborne particles are continually being circu- lated through the interior environment. A LakeAir unit removes these smoke, dust dirt, and pollen particles with an air purification process that works this way: 1.
  • Page 4: Installation

    REQUIRED To determine the number of HEPA / UV units required for your business establishments, use the method below as a guideline. If you have any questions, call the LakeAir HOTLINE at 1-800-558-9436 and we will help you. METHOD: UNITS PER ROOM VOLUME AND AIR CHANGES PER HOUR 1.
  • Page 5: Location Of Units In A Room

    HEPA /UVC protection. C. MOUNTING YOUR LakeAir MODEL LA2-RC2-HUV LakeAir provides a 8’ cord with every air cleaner, but it is the responsibility of the purchaser to provide adequate outlet which meets local codes. An approved extension cord may be used if it meets local and national codes.
  • Page 6: Operating Instructions

    In some cases it maybe necessary to mount this unit to a cart. The LA2-RC2-HUV has 4 1/4-20 nut inserts on the bottom of the unit. Using a 3/4" 1/4-20 screw, attach the air purifier to a sturdy cart through the cart top using rubber feet as a spacer.
  • Page 7 IV. Filter and UV Bulb Replacement NOTE: FAILURE TO Change Filters and Bulbs May Create a Hazard Pre Filter Wash every 4 month replace annually HEPA Filter -Every 6 months -Every 3 months Carbon Filter UV Bulbs -Annually...
  • Page 8: Filter And Bulb Replacement

    Filter and Bulb Replacement Carbon Filter Replacement The Activated Carbon filters play 2 vital rolls in the LakeAir LA2-RC1-HUV model. First they absorb harmful VOCs and they act as an UV Ray Shield. NEVER run the UV unit without Carbon filters installed. Serious damage can happen if people are exposed to unshielded UVC rays.
  • Page 9 Place the Rear UV Carbon Filter on the rear side of the UV Cell. This is the side where the power wires exit the UV Cell. Place the front UV Carbon on the intake side of the UV Cell. These filters must sandwich the UV Cell to provide extra protection from UV Rays.
  • Page 10 UV Bulb Replacement The UV Bulbs have a useful life of about 9000 hours. They should be replaced every year, While the bulbs may continue to function, they will do so at a less efficient rate. To remove the bulb rotate them 90 degrees and remove from the UV Cell Fixture.
  • Page 11: Repair And Maintenance

    DO NOT RETURN UNIT TO FACTORY WITHOUT AUTHORIZATION. RK Ventures Inc. 1509 RA PIDS DRI VE Ra c i n e W I 5340 4 1-800-558-9436 262- 632-3144 Web site: www.lakeair.com...
  • Page 12: Trouble Shooting

    B. TROUBLE SHOOTING ELECTRONIC AIR CLEANERS CAUTION: During repair procedures dangerous line voltage circuits are exposed; use care to avoid the hazard of electrical shock or possible damage to the unit. The following examples are used to aid the serviceman in trouble shooting any malfunction in the Electronic Air Cleaner quickly and properly.
  • Page 13: Replacement Parts List

    C. REPLACEMENT PARTS LIST - MODELS LA2-RC1-HUV Part # Description 300013 Reverse Curve Blower 100450 Variable Speed Controller 497592 LED Indicator 497546 Fuse Box 497657 Safety Interlock Switch 100690 Blower Capacitor 499300 UV Filter Cell 120121 UV Ballast 400270 UV Tube (G15T8) 810301 Activated Carbon Filter Kit 285300...
  • Page 14: Schematics

    ELECTRICAL SCHEMATIC MODEL LA2-RC1-HUV & LA2-RC2-HUV...
  • Page 15: Special Warnings

    Special Warnings Caution: Ultraviolet energy. Protect eyes and skin. This product utilizes UVC Bulbs to provide microbial sanitation. The light waves are invisible to the human eye but are extremely dangerous. This unit must be run with all safety devices and switches in working order.
  • Page 16: Unit Disposal

    LA2-RC2-HUV Unit Disposal When the useful life of your LA2-RC2-HUV unit has come to an end great care should be taken in disposing of the unit. Before disposing of the unit be sure all UV bulbs and ballasts have been removed and disposed in accordance with local regulations.
  • Page 17: Warranty

    In addition, RK Ventures, Inc. than manufacturing defects are the re- warrants the frame, skins, wiring in the sponsibility of the user of the LakeAir LakeAir Electronic Air Cleaner for an Electronic Air Cleaner and are not cov- additional six (6) years or a total of seven ered by the Warranty.

Table of Contents